_

~

l C-E Power Systems Tel. 203/688-1911 Cornbustion Engineenng. Inc.

Telex 99297 h

i 1000 Prospect Hill Road q/

Windsor. Connecticut 06095 mw EE s?fas

- m v. n 3 D *w Sn q ', ' ' lg C

,[/

(,

License SNM-1067

/

ggV,'

q Docket ]_0-1100 September 9, 1981

~6-y '., '

f "';f*%%

193, 7

/[

%re l'h U. S. Nuclear Regulatory Commission v

'#3"c

[g%

Washington, DC 20555 5

Mr. C. E. MacDonald, Chibfd., ~

. v 4-j 5 p' % 1981;,. [eb'.

w Attention:

Transportation Branch h

rQ Division of Fuel Cycle & ilaterial Safety j

Reference:

Docket No. 71-6294

~_

Dear Mr. MacDonald:

Cembustion Engineering, Inc. is a registered user of the UNC-2901 package, Certificate of Compliance 6294. Differences between handling procedures at C-E Hematite and C-E Windsor have indicated that improved utilization can be achieved by a n.odifica. tion of the internal pellet package. This letter is to request y]ur review, approval, and subsequent revision of Certificate of Compliance 6294 to permit pellet packaging either by the currently licensed or proposed method.

Part 5(b)(2)(i) of Certificate of Compliance 6294 indicates that sintered pellets shall be packaged in accordance with Combustion Engineering, Inc.

Drawing No. D-5008-8192, Rev. 05. This packaging method includes corru-gated polyethylene coated steel trays. These trays are stacked together.

A sponge rubber and wood slab is placed at the top and bottom of the stack to make up the pellet package.

The alternate arrangement for which your approval is requested is shown in Combustion Engineering, Inc. Drawing No.

NFil-E-4266, Rev. O.

The proposed packaging method utilizes covered steel trays which are stacked to a maximum of 20 trays (5 high x 4 deep). The new arrangement will be limited to the quantities and weights presently licensed.

The criticality safety analysis for the presently licensed packaging method will continue to be valid for the proposed method.

Subcriticality is pres-

{

ently assured by a maximum credible H/U235 ratio of 205. Ratios below 205 were found to be less reactive.

In the proposed new packaging arrangement, solid steel pellet trays are utilized in place of the polyethylene coated corrugated steel pellet holders. The proposed arrangement has a reduced l

hydrogen content resulting in a decreased H/U235 ratio and lower reactivity.

Sd U/ - 2. -

MPU311........3l.........

h.a. C.7.3.O.

ThaO ha C& ;otj..M./.t.O

" " '.#0Ch".kRevdSb h M

8110160225 810909 c?/ L PDR ;oived Gy.pc/ggy.[Jl...

PDR ADOCK 07001100 C

e,,,

k.

Also,.the presently licensed inner packaging contains approximately 6.57% steel by volume whereas the proposed inner packaging will contain over 11.23% steel by volume. The increased steel content will more effectively poison the system and lower the reactivity even further.

It is thus concluded that the proposed new inner packaging arrangement will re-main subcritical during conditions normally incident to transportation as well

'as during all credible accident conditions.

The present structural evaluation is also applicable since the UNC-2901 outer and inner container and net weight of packaging will not be changed utilizing the proposed packaging method.

If you have any questions with respect to the proposed revision of Certificate 6294, or if additional information is needed to complete your review, please contact Mr. G. A. Johnstone of my staff at Ext. 3150.

A check in the amount of $350.00, the minar amendment application fee specified y

in 10 CFR 170.31, Part llD has been sent directly to the License Fee flanagement Branch under separate cover.

Very truly yours, H. V. Lichtenberger Vice President-Nuclear Fuel Nuclear Power Systems-Manufacturing HVL/GAJ/ssb Enclosure -

r

-^

O W

e Q

u e

J

.d. l j

g fIdj g

f

__. i 7

11 ge 4

l 5

35

~

(

i e

s

\\

k'N W~

\\

k!i al,

! (ij 3llai

~

i i l

i

\\.

\\'

y

~

=

S I

~

EU i

DL

\\.-

f I

"Il r

ii 8523

'N-.

J gogg ii!!

.T-

\\

o

'jba 3,!$

/

d

\\

da 1

s

=

-s

\\

ag 333

.s- -./s

$as

\\

em c

a 38 1"

et if$

/

is!

x x

s agi

\\

3

!$3 g

3

\\

z p5]g

$nd

\\

g

!i!

\\

3

/

\\

t s

/

/

u x

i

  • 15 e

j9

\\

x.

i N

so

\\

3i I

O se d

ei W!

~

c

/

l a:

^

??,l?

$i

~

g

?

/

l v p03

/

- ~. -

I"TRAllSPORTATI0Il APPROVALS" Docket No.

2/- 6 2_9 [

Hilliam O. Miller License Fee Managemen'. Branch Office of Administration MATERIALS TRAL;SPORTATIO!1 APPROVAL CLASSIFICATI0ll Applicant: C / [<b% broMt te>

.f/

Approval l'o: /9 9 9 Y Fee Catecory MI Application Dated: 2/9/#/

Received: 7//E/P/

Applicant's Classification: /7%tAv

- // A The above application for amendment has been reviewed by the IP!SS Transportation Branch, in accordance with Section 170.31, and is classified as follows:

1.

Amendments to Acorovals in Fee Catecories 11A throuch 11E (a)

Major (b) A nor (c)

Administrative h

2 Justification for reclassification:

F A s.

.usMu W AA

,- A - M,%

p-9 a

g 3.

The application was filed (a) pursuant to written !!RC request and the amendment is being issued for the convenience of the Comnission, or (b)

Other (State reason):

f Signature: (mob Transportatf on Branch, !!'.SS Date:

9//(o/7/

  • we m g

1-_r_r'_- -n_ ~ _