. t, '. r t

,5 s

PHILADELPHIA ELECTRIC COMPANY 23O1 M ARKET STREET P.O. DOX 0699

~ OUI PHILADELPHI A PA.19101 1,7l :,.=,"

SEP 291981

{}

[ g~ ([

!ir. Ronald C. Haynec, Director Office of Inspection and Enforcement, Region I

.9

_g United States Ituelear Regulatory Commincion OC7

-4 O Q[]

631 Park Avenue

/

P' o, Ti';g,%

j 1

19406 King of Pruccia, PA w,r s

N SlTBJECT: Significant Deficiency Report tio. 38 Interin Report IIo. 3 on Defects in s

Lialtorque Valve Motor Operators Limerick Generating Station Units 1 and 2 IIRC Construction Permit IIos. CPPR-106, 107 REFEREIICE: 1) Telecon, H. R. Walters (PECO) to E. C. McCabe (U3ffRC), May 1,1981

2) Interim Report lio.1, J. S. Kemper (PECO) to B. H. Grier (UGflRC), May 28, 1981
3) Interim Report 170 2, J. S. Kemper (PECO) to B. H. Grier (USilRC), July 28, 1981 FILE: QUAL 2-10-2 (SDR 38)

Dear Mr. Haynes:

'Ihis is oar third interim report regardind certain deficiencies in Limitorque valve motor operatora supplied for use at Limerick Generating Station.

Previous information was forwarded to you via the referencec.

I Ihe inspection of a cample of t6 Limitorque motor operators has been completed and the incpection data cheets have been reviewed by the engi-neering organizations of both PECO and Dechtel. A cignificant number of operators have at leact one of the following deficiencies: limit swltch rotors with cracks or micdrilled pin holes, use of nonqualified terminal blocka, use of nonqualified heaters, improperly cet torquo switch limiter plates, use of fiber, rather than metallic, washern ur. der the torque switch'n contact cerews, and damaged guckets.

Q7 5

/ O 81100902S1 810929PDR ADOCK 0S0003S2 l

PDR S

W u

Mr. Ronald C. Haynes Together with Bechtel Power Corporation, we are continuing to fomulate a program to inspect all safety related operators and correct the deficiencies found.

This is taking somewhat longer than we had originally expected due to the numerous different problems that have been found in the Limitorque operators and our desire to adequately inspect for and correct then all at the same time.

We will submit a further report on this subject by December 31, 1981.

Sincerely, Copy to:

J. P. Durr, LGP Resident USNRC Inspector Director of Inspection and Enforcement United States Nuclear Regulatory Coranission Washington, DC 20555 RJL:dr