Form NRC418 U.S. NUCLEAR REGULATORY COMMISSION U

CERTIFICATE OF COMPLIANCE 10 C R 71 For Radioactive Materials Packages 1.(a) Certificate Number 1.(b) Revision Ivo.

1.(c) Packaoe identificatior. No.

1.(d) Pages No. 1.(e) Total No. Pages 5059 8

USA /5059/AF 1

2

2. PRE AMBLE 2.(a)

This certificate is issued to satisfy Sections 173.393a.173.394.173.395, and 173.396 of the Department of Transportation Hazardous Materials Regulations (49 CFR 170189 and 14 CFR 103) and Sections 146-19-10a and 146-.19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amended.

2.(b)

The packaging and contents described in item 5 below, meets the safety standards set forth in Subpart C of Title 10, Code of Federal Regulations, Part 71, Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions.**

2.fc)

This certificate does not relieve the consignor from compliance with any recuirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or into which the package will be transported.

3. This certificate is issued on the basis of a safety analysis report of the package design or application-3.(a)

Prepared by (Name and address):

3.(b)

Title and identification of report or application:

Nuclear Fuel Services, Inc.

Nuclear Fuel Services, Inc. application P.O. Box 218 dated March 27, 1981.

l Erwin, TN 37650 3.(c)

Docket No. 71-5059 4 CONDITIONS This certificate is conditional upon the fulfilling of the requirements of Subpart D of 10 CFR 71, as applicable, and the conditions specified in item 5 below.

5. Description of Packaging and Authorized Contents, Model Number, Fissile Class, Other Conditions, and

References:

(a) Packaging (1) Model No.: NFS Uranyl Nitrate Tank Trailer (2)

Description Bulk liquid insulated cargo tank trailer.

The 3,800 gallon tank trailer is of all welded construction of type 304L stainless steel.

(3) Drawing i

The tank trailer is constructed in accordance with DOT specifications MC-310, MC-311, or MC-312.

l (b) Contents

(

i (1) Type and form of material I

l Uranyl nitrate in dilute acid solution.

The maximum U-235 enrichment in the uranium must not exceed 20% by weight.

The U-235 content of the solution must not exceed 10 grams per liter.

4 4

+ei10090085 810921 PDR ADOCK 07105

.C

Page 2 - Certificate No. 5059 Revision No.~8 - Docket No. 71-5059 5.

(b)

Contents (continued)

(1) Type and form of material (continued)

The total uranium content must not exceed 357 grams per liter (1.5M).

The UO (NO )2-6H 0 content must not exceed 50 weight percent.

The-2 3

2 HNO3 concentration will be normally 0.4M.

The freezing temperature of any of the solutions must be less than 32 F.

(2) Maximum quantity of material per package Not more than 45,600 pounds net weight of uranyl nitrate acid solution.

(c)

Fissile Class III Maximum number of packages per shipment One(1) 6.

The solution must be at a temperature of 68'F or above at the time of packaging.

7.

Prior to delivery to a carrier for transport, for U-235 enrichments greater than 4% by weight the shipper must ensure that at no point along the proposed shipping route that the ambient temperature will be less than 32 F.

In the event freezing weather is encountered the administrative procedures and controls as specified in Nuclear Fuel Services, Inc. application dated March 27, 1981, must be complied l

with for all U-235 enrichments.

8.

The package must be tested and maintained in accordance with Section 8.0 of the Application.

9.

The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).

10.. Expiration date: September 30, 1986.

REFERENCE ~

Nuclear Fuel Services, Inc. application dated March 27, 1981.

FOR THE U.S.' NUCLEAR REGULATORY COMMISSION L

N.,

Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety SEP 211981

-