Text
.
s I
YANKEE ATOMIC NUCLEAR POWER STATION MONTilLY STATISTICAL REPORT 76-5 FOR TIIE MONTH OF MAY, 1976 8110060644 760604.
PDR ADOCK 05000029 R
W APPENDIX C 760604
' DOCXET NO.
50-29 DATE
~~'
4 UNIT MAME YANKEE RONE OPERATING PLAhT DATA
. COMPLETED BY E. C. TARNUZ2.ER TELEPHONE (617) 366-9011 X276 EEE E AII N E SI Alg S q
1.
REPORTING PERIOD:
May 1976 GROSS if0URS IN REPORTING PERIOD 744 2.
CURRENTLY AUT110RIZED POWER LEVEL MWt 600 MAX. DEPEND. CAP. (MWe-NET) 175 DESIGN ELECTRICAL RATlNG (MWe-NET) 175 3.
POWER LEVEL TO WilIOl RESTRICTED (IF ANY):
538 MWt (ev MO fl@c.)
4.
REASONS FOR RESTRICTIONS (IF ANY):
Peak linear heat rate limit to comply with ECCS performance criteria of 10CFR50.46.
TilIS CUMULATIVE MONTil YR-TO-DATE TO DATE 5.
HOURS REACTOR WAS CRITICAL 426 2869 112,266 6.
REACTOR RESERVE SHUTDONN HOURS 0
0 0
422 2790 10S,246 7.
IIOURS GENERATOR ON-LINE 0
0 0
8.
UNIT RESERVE SliUTDOWN 1100RS 9.
GROSS THERMAL POWER GENERATED (MWil) 232,J25 1,389,655 57,038,743
.68,961 434,792 17,500,344 10.
GROSS ELECTRICAL POWER GENERATED (MWH) 64,374 405,652 16,375,814 11.
NET ELECTRICAL POWER GENERATED (MWil) 57.2 73.7 81.2 12.
RFACTOR SERVICE FACTOR 57.2 79.3 80.6 13.
REACTOR AVAILABILITY FACTOR 56.8 76.5 79.4 14.
UNIT SERVICE FACTOR 56.8 88.8 15.
UNIT AVAILABILITY FACTOR 49.4 63.6 71.6 16.
UNIT CAPACITY FACTOR (USIhG MDC) 63.6 71.6 17.
UNIT CAPACITY FACTOR (USING DESIGN MWe) 18.
UNIT FORCED OUTAGE RATE 0.0 16.1 1.5 19.
SHUTDOWNS SCllEDULED TO BEGIN IN NEXT 6 MONTIIS (STATE TYPE, DATE AND DURATION OF EACH): None.
I N.A.
20.
IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP:
ffuh A@ 'LL
~-
DOCKET NO.
50-29 g;
UNIT NAME YANKEE RONE DATE 760604 COMPLETED BY E. C. TARNUZZER' APPENDIX D TELEPl!0NE' (617) 366-9011 X 276 UNIT SHUTDOWNS AND POWER REDUCTIONS REPORT MON 111 May 1976 TYPE METHOD OF F-FORCED DURATION SliUTTING DOWN NO.
DATE S-SCllEDULED
(!!OURS)
REASON (1)
THE REACTOR, (2)
CORRECTIVE ACTIONS /COSBfENTS 76-5 760506 S
322 A
2 Shutdown to install repaired generator exciter and to plug tubes in steam generator.
)
760524 S
A y
pad 7:ductionto.90MWEtoplugtwotubes O
in co. denser.
I i
l SUSBIARY:
Full load limited to 89% for ECCS performance criteria (10CFR50.46). One shutdown to return repaired-generator exciter to service and plug 2 tubes in one steam generator. One load'r' eduction noted to permit isolation of b of condenser water box and plugging of two tubes.
Rev. 10/75 l
APPENDIX Il e
DOCKET No.
50-29 UNIT YANKEE ROWE DATE 760604 COMPLETED BY E. C. TARNUZZER TELEPHONii (617) 366-9011 X 276 AVERAGE DAILY UNIT POWER LEVEL MONTH May 1976 DAY
'v ;dGE DAILY h"de-net DAY AVERAGE DAILY MW -net 2
1 153 16 0
0 2
152 17 0
3 152 18 0
4 152 19 77 5
154 29 152 6
146 21 155 0
27 7
154 0
23 8
140 0
24 9
145 10 25 156 0
11 26 0
159 12 27 159 13 0
28 158 0
29 14 158 15 0
39 158 31 i
Rev. J0/75 1