ML20030C522

From kanterella
Jump to navigation Jump to search
Proposed Changes to ETS Section 4.1.2(e) & Table 4-3,re Shoreline Seine Survey
ML20030C522
Person / Time
Site: Arkansas Nuclear 
Issue date: 08/17/1981
From:
ARKANSAS POWER & LIGHT CO.
To:
Shared Package
ML20030C521 List:
References
NUDOCS 8108260196
Download: ML20030C522 (2)


Text

l 4-29 i

TABLE 4-3 AQUATIC SAMPLING LOCATION AND FREQUENCIES Sample Type Sample Frequency Sample Station #

Plankton Quarterly - January, April 1, 2, 3, 5, 10, 11, July, October 14, 15, 16, 21 Benthic Organisms Quarterly - January, April A,

2, 3, 5, 10, 11, i

July, October 14, 15, 16, 21 Gill Net Survey 2 sets of 2 net-nights in Areas A, B, C, D l

each area within 30 days I

of each quarter Trawling Survey Two samples in each area Areas A, B, C, D every other week March, April, May, June Trap Net Survey 5 consecutive days Areas, A, B, D Spring and Fall Cove Rotenone Survey September Areas A, C Shoreline Seine One sample in each area Areas A, C Survey every other week April, May, June Fish Cage Survey Semi-annually Areas A, B, C, D l

(Mussels) l Chemical Monthly 1*,

3, 5, 7, 8, 10, l

11, 13, 14, 15, 16, l

17, 21 Physical Monthly 3, 5, 7, 8, 10, 11 13, 14, 15, 16, 17, 21 l

l l

l l

8108260196 810817,i PDR ADOCK 05000313 P

PDR I

. - -... -. _ _.... _ ~., _ _ _ _. _ _ _ _ _, _

4-9 i

b)

Trawling Survey Samples will be taken every other week during l

March, April, May, and June.

Emphasis will be on larval fishes.

Relative abundance and species composition will be determined.

Spines, scale samples and length / frequencies shall be obtained for representatives of each species.

Population count and species shall be reported.

c)

Trap Net Survey l

Trapnets shall be placed out in the spring and i

fall each year with lifts made for five (5) l consecutive days.

Spines, scale samples and l

length / weight frequencies shall be obtained for representatives of each species.

Population count and species shall be reported.

d)

Cove Rotenone Survey The cove rotenone survey using standard procedures i

approved by the Arkansas Game and Fish Commission shall take place in sample area 18 and " control area" 19-in September.

Spine, scale samples and l

length / weight frequencies shall be obtained for i

representatives of each species, and growth rate i

shall be determined.

Population counts shall be i

reported.

e)

Shoreline Seine Surveys Shoreline seining shall provide data on fish spawning and fingerling population. The positions for shore-line seining operations shall be chosen in areas characteristic of fish spawning.

This, along with the trawling survey, will provide-infcrmation relative to the peak spawning period and the relative abundance of these fishes.

This operation stall take place during the spawning season beginning in April, and in May and June to survey fingerlings.

f)

Fish Cage Survey Cages containing mussels shall be placed at sample stations shown in Table 4-3 and marked for recovery.

Mussel samples shall be recovered semi-annually and retained for radiological testing.

,~%--mw.c-

-m.

,.-r--.-,,#.,..c-

..-.w,

,.,,yy---.--w,

,,--.,-e-.

--,,. =

__en-w+-.-w, e,-