Discusses 741105 Amend 8 & Tech Specs Change 45 to License DPR-6 Re Interim Surveillance Requirements Pending Completion & Acceptance of Certain Mods.Mods Will Assure Plant Ability to Withstand Postulated Rupture Consequences
ML20030A546
Person / Time
Site: Big Rock Point File:Consumers Energy icon.png
Issue date: 12/09/1974
From: Sewell R
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: Goller K
US ATOMIC ENERGY COMMISSION (AEC)
References
NUDOCS 8101090979
Download: ML20030A546 (3)


Text

.-a O*

y

~

i c

Consumers C

POWcr g-

~

C0mpany 33.f.

f;, cyg DG*f4 fywx

-derterat Offices: 212 West Michigan Avenue. Jackson, Michigan 49201. Area Code 517 788-OSSO I'I. ' Oc N

n.,

N ]

December 9, 197h zf&Q Yl&Q': Dif'i s

Q/'

Y:

Dj o f :j/ ])s C a

et

/j/g '-

7l 4'e:

Docket 50-155 Mr. Karl Goller f

License DPR-6 Assistant Director for Jj Operating Reactors

\\l f

s/

Big Rock Point n',

'. yJ Directorate of Licensing US Atomic Energy Commission N-Washingtun, DC 20545

\\

7 l

Dear Mr. Goller:

By letter dated November 5, 19Th, the AEC issued Amendment 8 and Technical Specifications Change No 45 to Facility License No DPR-6.

That anndment and accompanying Technical Specifications Change added Interim Surveillance Requirements to the Technical Specifications for the Big Rock Point Plant pending completion and acceptance of certain modifications to the plant to assure that it will withstand the conse-quences of postulated ruptures in the high energy fluid piping outside containment without loss of capability to achieve and maintain safety shutdown of the facility. That letter requested that Consumers Power Company inform the AEC of the schedule for completion of the proposed modifications to the plant relating to the high energy fluid piping system. Consumers Power Company presently plans to complete the modi-fications (described in the Safety Evaluation attached to the November 5, 1974 letter) during the 1975 refueling outage that is presently scheduled to commence about mid-September 1975 In a telephone conversation, I had previously stated that I felt Consumers Power Company would be able to complete these modifications by July 1975 This statement was made in early 1974 and assumed _that finsl AEC approval of the modifications would be forthcoming within several months and that our 1975 refueling outage would accur in the first half of 1975 After receipt of Amendment 8, I discussed the requirements of the revised Technical E7ecifications with a member of the Directorate of Licensing staff to eo'ure that I fully understood them. One typo-graphical error was identified and I understand it will be corrected by the AEC in the near future. This typographical error was in the revised Paragraph h.l.2(c)3(a):

the number "h.6k" should be " Table 9 3(b)."

e

.1 y 'h n. }

LL r s.

9163 @90

t Mr.'Karl Goller 2

Docket 50-155, License DPR-6 Big Rock Point December 9, 197h Further, with regard to the asterisk on Table 9 3(b) requiring the. volumetric inspections to be completed within _three months of the iscuance of this change, it was stated that this requirement could be ful-filled by previous examinations performed on the velds in the piping identified.. Over 50 percent of the velds in the identified piping have been examined during the past several years. The remainder will be examined during our surveillance _ outage which is scheduled to occur during January 1975 This will fulfill the volumetric examination requirements of Table 9 3(b).

The requirement of the periodic visual leakage check was also discussed.. I was it.cormed that this periodic leakage inspection was meant to be an inspection of the piping in the as-found condition at the present time -and that the insulation need not be removed to perform this inspec-tion. The insulation vould be removed only if the results in the visual inspection indicated that a leak may exist.

Item h of the change states", in part:

".... The inservice examinf ion and the frequency of inspection vill provide a means for timely detection and need only be in effect until required modifications are complete." I was informed that this statement applied to Technical Specifications Change No h5 in its entirety. We vill, therefore, consider the requirements of Technical Specifications Change No h5 to the Technical Specifications to be null and void when the mod'fications described in the safety evaluation have been completed.

Yours very truly, ux RBS/ map Ralph B. Sewell Nuclear Licensing Administrator CC: JGKeppler, USAEC l

P

,e

\\

l 8

AEC DISTRIEUTION FOR PART 50 DOCKET r.1ATERIAL (TEMPORARY FORM)

CONTROL NO:

12429

{

r FILE:

FROM: Consumers Power Company DATE OF DOC DATE REC'D LTR TWX RPT OTHER Jr.ekton, Michigan 49201 Ralph P. Seve11 12-9-74 12-11-74 x

TO:

ORIG CC OTHER SENT AEC PDR vv SENT LOCAL PDR XX Mr. Karl Goller 1 siened 39 CLASS UNCLMS i PROPINFO INPUT NO CYS REC'D DOCKET NO:

XXX 40 50-155 DESCRIPT;ON:

Ltr re our 11-5-74 ltr.....

ENCLOSURES:

furnishing addl inior mation re Tech Specs for the Big Rock Plant......

00I$0$E.C:Il0'.'O I.rory,.

U RL A...

PLANT NAME:

Fig Rock Point FOR ACTION /INFORT.1ATION m

19.1 p _%

BUTLER (L)

SCHV!ENCER (L) diEMANN (L)

REG AN (E)

W Ccases W! Cnpics W,$opies W/ Copies CLARK (L)

ST0 Z (L)

DICKER (E)

LE AR (L)

W/ Copies W/ Copics W/ Copies W/ Copics PARR (L)

VASSALLO (Li KNIGHTON (E)

W/ Copies W/ Copies W/ Copies W/ Copies KNIEL (L)

PURPLE (L)

YOUNGBLOOD (E)

W/ Copics W/ Copies W/ Copies W/ Copies INTERNAL DISTRIBUTION 85EG FI_LD TECH REVIEW DENTON

_ LIC AGST_

A/T IND AECPDM G R!i.;ES BR AIT AN DGC. ROOM P ECGA SCHROEDER G AF.ll LL dlGGS (L)

SALTZM A.

diUNTZING.ST AF F MACCARY K ASTN E R GE ARIN (L)

8. HU RT CASE KNIGHT BALLARD GOULCOURNE (L)

GIAMBUSSO PAWLICKI SPANGLER KREUTZER (E)

PLANS DOYO SHAO LEE (L)

M;DO ML 400RE (L) (BWR)

STELLO ENVIRO M AIG RET (L)

C H AP'.l AN DEYOU :G (L) (F'J!R)

HOUSTON MULLER REED (E)

WUDE-jKOVHOLT (L)

NOVAK DICKER SERVICE (L)

t. COUPE KiOLLER (L)

ROSS KNIGHTON SHEPPARD (L)

P. CO LLINS IPPOLITO YOUNGBLOOD SLATER (E)

D. THOV:5C'! (2)

DENISE TEDESCO EGAN SMITH (L)

, KLECKER REG ODR LONG ROJECT LDR TEETS (L)

EISENHUT NIEE's fiEGION (1 L AIN AS

__Sf/[y__

WILLI AMS (E)

MOR R!S BENAROYA HARLESS WILSON (L)

,STEELE VO LlME R DQQD D

EXTE.RN AL DIST RICUTION f U U_ _R_

U,,

a/] - LOC AL PDR Charlevoix, Mich.

j 64 - T IC ( A C E R ' '.T H Y ) (1)(2)(10) - N ATION AL L ABS _

1 - PDR SAN!L A/NY 8(- NS!C ICUCH A.' AN) 1 - ASLBPtE W Bt M. % 529) 1 - B ROOK H AV E.'.

' 7 L A5 1 - ASLB 1 - W. PE'. :lNGTON Rm E 201 GT 1 - G. ULRIKE07:. C ' :.L 1-te.emoAm -mn 1 - B&Y E/MEEROAD. Gm E 201 GT 1 - A GT. ED tRUTF UL IIA' NG - ACRSXXJM~.OCG SENT To 1 - CO'.SULT J:TS R m e 12? 'iT LIC. AST. R. DIGGS 12-12-74 NE?..'.l ARK. SLUM E AG BASI AN 1 - R. D. MUELLE R. Rm E 20' GT

.