Forwards Request for Change 41 to Tech Specs,Clarifying Tech Specs Intent Re Low Steam Drum Level Trip Setpoint
ML20030A346
Person / Time
Site: Big Rock Point File:Consumers Energy icon.png
Issue date: 11/05/1973
From: Dewitt R, Lamley R
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: Oleary J
US ATOMIC ENERGY COMMISSION (AEC)
References
NUDOCS 8101090358
Download: ML20030A346 (4)


Text

.

- ~......

'r.

,?.

ConsumBIS

~~

POV.'Cf C0mpany General Offices. 212 West Michigan Avenue., Jackson, Michigan 49201. Area Code 517788-0550

~ ~ '

November 5, 1973

(,,,(p * " ~ ~,,., ;

7 s-v, C.

' y' sn \\ r d 1)

Iljli.t

[(. Y t

v

(-

Y NQV T1973%

Mr. John F. O' Leary, DireEt' r z["

Re: Docket No 50-155 o

Directorate of Licensing

,'.x,

.Ir License No DPR-6 US Atomic Energy Commission \\',ffg g Washington, DC 20545 Tech Spec Change Request No 41 Dear Mr. O'Learyi Transmitted herewith are three (3) executed and thirty-seven (37) conformed copies of a Request for Change to the Technical Speci-ficetions of License No DPR-6, Docket No 50-155, issued to Consumers Power Company on May 1, 1964 for the Big Rock Point Plant.

This change (No kl) is proposed only to clarify the intent of the present Technical Specifications with regard to the low steam drum level trip set point.

e.

Yours very truly,

)

CLp AQ1-< )

RBS/ map Ralph B. Sewell Nuclear Licensing Administrator CC: JGKeppler, USAEC A

I5 o.,

+

0 NCIETIA mm Tl NOV 7 1973 '

ESEI[i muu ux C}

NSI ll

\\

~

,x CONSU)CRS POWER COMPANY Docket No 50-155 Request for Change to the Technical Specifications Change No h1 License No DPR-6 For the reasons hereinafter set forth, the following change to the Technical S.ecifications of License No DPR-6 issued to Consumers I

Power Company on May 1, 196h for the Big Rock Point Plant is requested:

I.

Section 6, Table 6.1.2 Reactor Safety System During Power Operations Change low steam drum level scram setting from:

"8.0 i 0.5 inches below operating level" To:

"Not lower than 8 5 inches below steam drum center line."

II.

Discussion The " low steam drum water level" trip is an anticipatory type of trip which indicates a loss of water condition that could lead to low water level in the reactor. The trip set point was established prior to plant operation as being 8.0 1 0 5 inches below the operating level, which at that time was envisioned to be the drum center line. The plant oper-ating history has shown that the normal v'ater level in the drum during power operation varies from end to end by approximately 4 inches. This end-to-end variation is power level dependent.

There are four water level sensors associated with the steam drum, two at each end. The set points for the trip devices associated with these sensors have been established at 8.0 i 0 5 inches below the drum center line. The drum center line has historically been considered to be the aormal operating level even though the water level at one end of the drum has been at or a few inches below the drum center line, while the water level at the other end of the drum has been at or several l

inches above the drum center line.

If one considers the actual water level at each end of the drum individually and demands a literal inter-pretation of the Technical Specifications, he would conclude that we were not operating in conformance with the requirements for the " steam drum

(

2 W

water level" t

'n setting. Changing the low steam drum vater level trip setting requirement from 8.0 1 0 5 inches below normal operating level j

to less than 8 5 inches below the drum center line vill eliminate the difficulties in interpretation.

III. Conclusion Based on the foregoing, we have copeluded that this proposed change does not involve an unreviewed safety consideration or a sig-P nificant hazards consideration.

CONSUMERS POWER COMPANY 0 A

' (.,-J. 'Y.(L 1

By R.A.Lamley,VicePresgdent Sworn and subscribed to before me this 5th day of November 1973

.b /br l

t

^L 4 Sylvia B. Ball Notary Public, Jackson County, Michigan My commission expires May 18, 1976 1

9 I

e T :

AEC D' ~'RIBUTION FOR PART 50 DOCKET Mr RIAL 8084 (TEMPORARY FORM)

CONTROL NO:

/

FILE:

FROM:

DATE OF DOC DATE REC'D LTR MEMO RPT OTHER 1

1 Consumers Power Conpany Jackson, Mich. 49201

r. R. B. Sewell 11-5-73 11-7-73 X

~

TO:

ORIG CC OTHER SENT AEC PDR vvy J.F. O'Learv 3 signed CLASS UNCLASS PROP INFO INPUT NO CYS REC'D DOCKET NO:

XXX XXX 40 50-155 DESCRIPTION:

ENCLOSURES:

Ltr trans proposed change No (41) to the Proposed Chance to Tech Specs No. 41, tech specs....trans the following......

notarized 11-5-73, to license No. DPR-6.

(40 cys encl rec'd) f PLANT NAME:

Big Rock Point DO NOT EEMOVE FOR ACTION /INFORMATION 11-7-73

.T B BUTLER (L)

SC157ENCER(L)

  1. ZIDIANN(L)

REGAN(E)

W/ Copies W/ Copies W/9 Copies W/ Copies CLARK (L)

STOLZ(L)

LICKER (E)

W/ Copies W/ Copies W/ Copies W/ Copies GOLLER(L)

VASSALLO(L)

KNIGHION(E)

W/ Copies W/ Copies W/ Copies W/ Copies KNIEL(L)

SCHEMEL(L)

YOUNGBLOOD(E)

W/ Copies W/ Copies W/ Copies W/ Copies INTERNAL DISTRIBUTION

(/REGFILE TECH REVIEW DENTON A/T IND

/AEC~TDR HENDRIE GRIMES

,LIC ASST BRAIDIAN

~

V OGC, ROOM P-506A 3CHROEDER CAMMILL

/DIGGS (L)

SALTZMAN

/MUNTZING/ STAFF MACCARY KASINER GEARIN (L)

B. HURT CASE KNIGHT BALLARD GOULBOURNE (L)

PMNS CIAMBUSSO PAWLICKI SPANGLER LEE (L)

MCDONALD BOYD SHA0 MAIGRET (L)

  1. DUBE MOORE (L)(BWR)

STELLO ENVIRO SERVICE (L)

DEYOUNG(L)(IVR)

HOUSTON MULLER SHEPPARD (E)

INFO

/ SKOVHOLT (L)

NOVAK DICKER SMITH (L)

C. MILES P. COLLINS ROSS RNIGHTON TEETS (L)

/ Cabell IPPOLITO YOUNGBLOOD WADE (E)

/ REG OFR TEDESCO REGAN WILLIAMS nn nD 2 AI FILE & REGION (3)

LONG PROJECT LDR WILSON (L MORRIS LAINAS UU U I1I U 5 E1Ila.

STEELE BENAROYA HARLESS VOLDfER EXTERNAL DISTRIBUTION i-1 - LOCAL PDR g/

VI - DTIE(ABERNATHY)

(1)(2)(10)-NATIONAL LAB'S 1-PDR-SAN /LA/NY

  1. 1 - NSIC(BUCHANAN) 1-ASLBP(E/W Bldg,Rm 529) 1-GERALD LELLOUCHE 1 - ASLB(YORE /SAYRE/

1-W. PENNINGTON, Rm E-201 GT BROOKHAVEN NAT. LAB WOODARD/"H" ST.

1-CONSULTANT'S 1-AGMED(Ruth Gussman)

  1. 16 - CYS ACRS WOM>MM Sent to-Diggs NEWMARK/BLUME/AGBABIAN RM-B-12 7, CT.

11-7-73 1-GERALD ULRIKSON...ORNL l-RD.. MULLER..F-309 G

_