ML20029F008

From kanterella
Jump to navigation Jump to search
COL Docs - Vogtle Units 3 and 4 - NRC Staff Questions on LAR 19-019 Audit (Public-Redacted)
ML20029F008
Person / Time
Site: Vogtle  
Issue date: 01/29/2020
From:
NRC
To:
NRC/NRR/DNRL
References
Download: ML20029F008 (3)


Text

From:

Habib, Donald Sent:

Wednesday, January 29, 2020 4:23 PM To:

Vogtle PEmails

Subject:

Vogtle Units 3 and 4 - NRC Staff Questions on LAR 19-019 Audit (Public-Redacted)

Attachments:

2020-01 Questions on LAR 19-019 Audit_Redacted.docx

Hearing Identifier:

Vogtle_COL_Docs_Public Email Number:

528 Mail Envelope Properties (BL0PR0901MB366747C3D95FD5BD7A877C1C97050)

Subject:

Vogtle Units 3 and 4 - NRC Staff Questions on LAR 19-019 Audit (Public-Redacted)

Sent Date:

1/29/2020 4:22:41 PM Received Date:

1/29/2020 4:22:44 PM From:

Habib, Donald Created By:

Donald.Habib@nrc.gov Recipients:

"Vogtle PEmails" <Vogtle.PEmails@nrc.gov>

Tracking Status: None Post Office:

BL0PR0901MB3667.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 6

1/29/2020 4:22:44 PM 2020-01 Questions on LAR 19-019 Audit_Redacted.docx 32449 Options Priority:

Normal Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Vogtle Electric Generating Plant Units 3 and 4 License Amendment Request 19-019 Staff Audit Discussion Topics January 29, 2020

1. Table A.4-4, in calculation APP-1278-GEF-084, Rev. 0 (pg. 20 of 165), shows the summary of the reinforcement in the air inlet hoop direction. This table appears to support proposed UFSAR Table 3H.5-9 in LAR 19-019.
a. The Seismic L/C and Values columns in proposed UFSAR Table 3H.5-9 do not appear to have been updated to match the supporting calculation.
b. A note in the supporting calculation explains that the upper and lower sections have been averaged. This note is not included in proposed UFSAR Table 3H.5-9.
2. Figures A.3-1 and A.3-2, in calculation APP-1278-GEF-084, Rev. 0 (pg.12-13 of 165),

show how a reduction factor () was determined for thermal load cases. The reduction factor was computed using [ ]a,c. It is unclear why [ ] a,c was used.

3. Proposed UFSAR Table 3H.5-2 lists the controlling load cases and associated forces and moments for the exterior wall at column line 1. The identified controlling load case for Elevation 82-6 to 66-6 does not account for accident thermal reactions or pipe reactions (i.e., load combination 7). It is unclear to the staff if this load combination was addressed for this section of the wall.