Text
.
o f
GENuclear Energy i
Generalriectnc Company v
115 Curtnei Averue. San. lase. CA 95125 l
April 28,1994 Docket No.52-001 i
Chet Poslusny, Senior Project Manager l
Standardization Project Directorate Associate Directorate for Advanced Reactors and License Renewal Office of the Nuclear Reactor Regulation
Subject:
Submittal Supporting Accelerated ABWR Schedule -
FMCRD Scram Times
Dear Chet:
Enclosed are the FMCRD scram times that George Thomas (NRC) and Dick Ose (GE) discussed on April 26,1994. These scram times are for the nominal charge pressure of 2134 psig and for the minimum allowable charge pressure of 1850 psig. This is the same information that was provided at an earlier date.
Please provide a copy of this transmittal to George Thomas.
Sincerely, L
l Jack Fox Advanced Reactor Programs cc:
Alan Beard GE)
Norman Fletcher DOE)
Dick Ose GE) l Joe Quirk GE) l 0
030103 d
\\\\
JNPJ4F 940505032'/ 940428 PDR ADOC? 05200001 C
j I
l l
ASWR FMCRD HCU N2 CHARGE PRESSURE VERSUS SCRAN TIME FOR CONSTANT VESSEL FRESSURE OF 1375 psig INITIAL N2 CHARGE PRESSURE = 130 kg/cm2g (1850 psig)
CASE 1:
XBUS = 10.0 TIME HCU N2 PRESSURE VESSEL PRESSURE RCD POSITION sec psig psig 0
1375
.00 1850 0
1375
.10 1850
.1 1375
.12 1848 1.8 1375
.18 1842 3.4 1375
.22 1837 10 1375
.37 1817 18.4 1375
.57 1792 25 1375 74 1773 32.7 1375
.93 1751 40 1375 1 13 1730 50 1375 1.43 1701 60 1 76 1672 1375 70.7 2 16 1641 1375 1375 79.3 2.54 1615 85.1 1375 2.84 1597 88 1375 3.02 1587 90 1375 3.14 1580 93.1 1375 l
3.39 1568 95.1 1375 3.57 1560
,9'7 3.79 1551 1375 99 1375 4.11 1539 99.5 1375 4.25 1534 l
1526 1375 100 4.53 l
e ABWR FMCRD HCU N2 CHARGE PRESSURE VERSUS SCRAM TIME FOR CONSTANT VESSEL FRESSURE OF 1375 paig CASE 2: INITIAL N2 CHARGE FRESSURE = 150 kg/cm23 (2134 psig)
KBUS = 10.0 TIME HCU N2 PRESSURE VESSEL FRESSURE 10D FOSITION sec psig psig I
.00 2134 1375 0
.10 2133 1375 0
.12 2131 1375
.3
.18 2120 1375 3
.22 2112 1375 5.5
.29 2097 1375 10
.53 2050 1375 25
.72 2013 1375 37.2 77 2004 1375 40
.94 1975 1375 50 1.12 1946 1375 60 1.39 1904 1375 75 1.68 1863 1375 90 i
1.78 1849 1375 95 1.82 1844 1375 96.9 1.86 1839 1375 98.9 1.88 1836 1375 99.8 1.88 1836 1375 100 l
l 1
l l
l l
l lr.-.--
,