Amend 54 to License NPF-47,revising TS Table 3.6.4-1, Drywell & Containment Isolation Valves by Adding Chilled Water Return from Drywell Isolation Valve
ML20029C010
Person / Time
Site: River Bend 
Issue date: 03/12/1991
From: Dick G
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20029C011 List:
References
NUDOCS 9103220288
Download: ML20029C010 (5)


Text

.

e

,\\,

UNITED STATES y' 4 g

NUCLEAR REGULATORY COMMISSION k

'l WASHINoToN, D. C. 20555 g

l GULF STATES UTILITIES COMPANY DOCKET NO. 50-458 RIVER BEND STATION, UNIT 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 54 License No. NPF-47 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by Gulf States Utilities Company (the licensee) dated January 7, 1991, complies with the standards and. requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, as amended, the provisions of the Act, and the rules and regulations of the_ Commission; C.

There is reasonable assurance:

(i) that the activities-authorized by-this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance-of this license amendment will not be inimical to the common defense and security or to the health and sidety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have L

been satisfied.

1 l

l l

l 9103220298 910312-PDR ADOCK 05000458 P

PDR

l

  • 2*

2.

Accordingly, the license is amended by chenges to the Technical i

Specifications as indicated in the attachment to this license amendment and Paragraph 2.C.(2) of Facility Operating License No. NPF-47 is hereby amended to read as follows:

(2) Technical Specifications and Environmental Protection Plan The Technical Specifications contained in Appendix A, as revised through Amendment No. 54 and the Environmental Protection Plan contained in Appendix B, are hereby incorporated in the license.

GSU shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

3.

The license amendment is effective as of its date of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION Wf George F. Dick, Jr., Acting Director Project Directorate IV-2 Division of Reactor Projects - III/IV/V Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance:

March 12, 1991 l

l

. ~ _. _ _ _ _ _ _ _ _ _

j ATTACHMENT TO LICENSE AMENDMENT NO. 54 FACILITY OPERATING LICENSE NO. NPF-47 i

DOCKET NO. 50-458 Replace the following page of the Ap;,endix "A" Technical Specifications with 4

the enclosed page.

The revised page is identified by Amendment number and j

contains a vertical line indicating the area of change.

The overleaf page is provided to maintain document completeness.

1 REMOVE INSERT 3/4 6-41 3/4 6-41 1

i b

i l

l ymg -s

  • ww:r+s'- he e'WM*-9

'tw'*w'1't--w**

'N'**

  • ' ' '"~~ " **
  • %*"'-'"'N^

s TABLE 3.6.4-1 (Continued)-

~<

g CONTAINMENT-AND DRYWELL ISOLATION VALVES cn SECONDARY PENETRATION CONTAlle9ENT E

SYSTEM VALVE NUMBER NUIEER BYPASS PATH Z

(Yes/No) l b.

Manual Isolation Valves 2.

Drywell(k)

Service Air Supply 15AS*V489 1DRB*Z45 No t

Instrument Air Supply IIAS*V79 1DRB*Z47 No Service Water Supply 1HVN*V532 1DRB*Z54 No Senrice Water Supply 1SWP*V205 1DRB*Z54 No Service Water Return 1HVN*V543 1DRB*Z55 No Service Water Return ISWP*V206 1DRB*Z55 No

} Air Sup. for Main Steam SRV 1SVV*V50 1DRB*Z107 No 2

Air Sup. for Main Steam SRV ISVV*V53 1DRB*Z112 No 4

Cont Atmos. Monitor Probe ICMS*SOV34A(,)

IDRB*Z500 No 9

Cont Atmos. Monitor Probe

'1 CMS *SOV34B('3 1DRB*Z430 No Cont Atmos. Monitor Probe ICMS*SOV34C ')

1DRB*Z499 No I

ICMS*SOV340(*))

1DRB*Z428 No i

4 Cont Atmos. Monitor Probe I

1DRB*Z333 No ICMS*SOV32A(')

Cont Atmos. Monitor Probe ICMS*SOV32G

  • 1DRB*Z335 No Cont Atmos. Monitor Probe c.

Other Isolation Valves 1.

Primary Containment (a)

(c) ff) 1XJB*23A Yes Feedwater Line IB21*A0VF03

)

II) 5 Feedwater Line 1821*VF010A 1KJB*Z3A Yes(I) 1821*A3VF03g)C)

I l

5 Feedwater Line 1XJB*Z38 Yes i

II) j I-Feedwater Line 1KJB*I3B Yes 1B21*VF010B