,.. _ _.
I bC 3 I
l I
fTD 2 2 103) f I
i' Docket No. 99990081 1
1 U. S. Department of EnattJy, Idaho Operations ATIN Mr. T. Rowlard, Actirg Director West Valley Du w aitration P2Vjoct Offloo i
P. O. Dox 191 West Valley, !# 14171 Gentlemen
Subject:
.161C TLD Monitorirn at West Valley, Ib.trth Quarter,1990 Enclosed is a ocpy of the TLD monitorirg results atnind the subject facility for the fourth quatter of 1990.
The large value noted for Station RJ is due to the proximity of this dosimeter to a waste storagc facility located at the site. Similar results have boon noted for each monitoring period.
Due to the high value normally recotikd at Station ihmter 11, the total exposure is the sum of tho values recorded on two TLDs, one of Wich is placed for the first half of the quarter, and the other for the secord half. 'Iho TID for the second half of the fourth quarter could not be located; thus the gruss exposure reported here is for roughly the first half of the quarter (Oct. 4 -
1 Nov. 10, 1990). A not value was not calculated.
Sincerely, 4
Or$ nal s!;,n g gy.
II2tri J. Cores Chief Robert J. Dores, ion Prota: tion Eff1uents Radiat Soction, IRSS Enclosure (s): As Stated oct Public Wm:t Rocn (PER)
Iccal Fublic Mannt Rocn (LIUI)
Nuclear Safety Information Center (NSIC)
State of New York OFTICIAL RECDRD 00P/
- em 9103050050 910222 i
RE01 GA999 EUSDOEI 99990001 ppg a
{
ff!/
040021 l
3
ITii
- 9 tm
Rcgion I Docket Roam (with cornirrences)
R. D. Iturt, IM'6 L.J. W w,IMI M. R. Empp, [18's J.11. Joyner, EtES J. Roth, 11CB
.dW RI:DRSS/48 RI:Il RI:[m[g Struchteycr Roth Dores
.y 2/22/91 2/22/91 2B(J/91 OFTICIAL REXDRD COIY
4 WII?. VAllL'Y TID DIRDCT DNIIOtMNTAL RAvIATICli !Otil'IORI!C RIIUIIIS Annoal date 9/17/90 Field placemant dato 10/04/90 Retrieval date 1/09/91 Readout date 1/24/91 Groc.s lionitorirg Period 130 days ( 9/17/90 - 1/24/91)
Field Ibnitorirg Ibriod 98 chys (10/04/90 - 1/09/91)
Transit Period 32 days Station Distance Direction Grtus D posuru liet D:posure Ifunber (miles)
(degrees)
(mR /128 days)
(nR / 90 dayn) 1 4.0 350 25.8 +/- 0.8 ; 3.9 21.1 +/- 0.8 1 4.6 2
3.6 144 20.0 +/- 0.6 ; 3.0 15.8 +/- 0.6 ; 3.9 3
1.5 92 MISSIlO 4
1.2 51 20.8 +/- 0.6 ; 3.1 16.5 +/- 0.6 ; 4.0 5
2.1 10 25.6 +/- 0.8 ; 3.8 20.9 +/- 0.8 ; 4.5 6
1.7 319 22.2 +/- 0.7 ; 3.3 17.8 +/- 0.7 ; 4.1 7
1.2 262 19.9 +/- 0.6 ; 3.0 15.7 +/- 0.6 ; 3.9 8
1.4 234 19.8 +/- 0.6 ; 3.0 15.6 +/- 0.6 ; 3.9 9
0.3 300 39.9 +/- 1.2 ; 6.0 34.1 +/- 1.1 ; 6.2 10 on-site 43 32.6 +/- 1.0 ; 4.9 27.4 +/- 0.9 ; 5.3 11
- on-site 334 525 +/- 16 ; 79 12 on-sito 83 70.4 +/- 2.1 ; 10.6 62.1 +/- 1.9 ;10.1 Transit Ebse 2.8 +/- 0.3 ; 3.1
=
Results are reported as Measurement +/- Randca error ; Total entr
('Ibtal error = Randcan + Systemtic)
- Due to the high value normally recortled at Station 11 umber 11, the total expccure in the sum of the values recorded on two TIlb, one of which is placed for the first half of the quarter, and the other for the socord half. 'Ibe TLD for the socorrl half of the fourth quarter could not be locatod; thus the gross exposure reported here is for roughly the first half of the quarter (Oct. 4 -
Nov. 10, 1990). A not value was not calculated.
\\