_ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _
iOh ]$l0G
,#g 68 # E Cg
UNITED STATES o
- },,y I,'g NUCLE AR F'EGULATORY COMMISSION
\\\\
\\
M $mHGTON D. C. 20555 v
t\\.....'f JAN 3 9 1991
]
Docket No. 9991124/88-01 Mr. D. Woolf, Manager Branch Operations General Electric Supply Company 12640 Knott Street Garden Grove, California 92641
Dear Mr. Woolf:
This letter addresses the inspection of your f acility at Garden Grove, California, conducted by Mr. K. R. Naidu of this office on August 10, 1988, and the discussions of his findings with you and Ms. C. Angelo at the conclusion of the inspection.
Release of this report was delayed due to the NRC's ongoing review of nonconforming and substandard vendor products.
The purpose of the inspection was to determine if surplus or refurbished molded case circuit breakers and otbar (lectrical equipment mentioned in NRC Information Notice 88-46, in
' d i r.
Supplement 1, were procured and resold
. ors to nuclear power plants. This either directly or through d.
inspection consisted of an exa..
sion of representative records, interviews with personnel, and observations by the inspector.
In accordance with 10 CFR 2.790 of the Commission's regulations a copy of this letter and the enclosed inspection report will be placed in the NRC's Public Document Room.
Snould you have any questions concerning this inspection, we will be pleased to discuss them with you.
Sincerely,
)
fN Edward T. Baker, Acting Chief Vendor Inspection Branch Division of Reactor Inspection and Safeguards Office of Nuclear Reactor Regulation
Enclosure:
Inspection Report 9991124/88-01 cc: Mr. A. E. Reisman Division Council General Electric Company 1285 Boston Avenue Bridgeport, CT 06601 i
9102040089 910130 PDR GA999 ENV0ENE 9991124 PDR
_