_

.___-____ -_ _ _-_

.

.

-

.

.

J M i .'

5 :1

Docket Nos. 50-352

i,

50-353

Philadelphia Electric Company

NITN:

hir. D. hi. Smith

Senior Vice President-Nuclear

Nuclear Group Headquarters

Correspondence Control Desk

P.O. Box 195

Wayne, Pennsylvania 19087-0195

Gentlemen:

Subject:

Inspection No. 50 352/90-27 and 50 353/90-27

This letter transmits the results of the routine resident safety inspection by hiessrs. T. Kenny,

L. Scholl, and his, hi. Evans from November 18 - December 31, 1990, at the Limerick

Generating Station, Limerick, Pennsylvania. The inspection consisted of document reviews,

.

interviews, and observations of activities. The results have been discussed with hir. Graham

.:

Leitch and hir. Jay Doering of your staff.

No violations were identified by the NRC during this inspection.

We appreciate your cooperation.

Sincerely,

. . ,

.

.

,.

a

,.

A. Randolph Blough, Chief

Projects Branch No. 2

Division cf Reactor Projects

y

Enclosure: NRC Region Iinspection Report 50-352190-27 & 50-353/90-27

,

OFF.lCIAL RECORD COPY

i

9102010026 910123

,' D \\

gDR

ADOCKOS0g2

. _________--_-------_j

.

___

.

.

.

Philadelphia Electric Company

2

cc w/encis:

rR. J. Lees, Chairman, Nuclear Review Board

A. hl. Leitch, Vice Presiient - Limerick Generating Station

A). R. Helwig, Vice President of Nuclear Enginceiing and Sern::s

J. W. Dt, tham, Sr. Vice President and General Cocncil

7

Doering, hianager - Limerick Generating Station

J

G. J. Beck, hianager - Licens ng Section

i

j . A. Hunger, Jr., Project hianager - Limerick Generating Station

G

-

f . F. O'Rourke, hianager Limerick Qaality Division

J

G. J. Stadsen, Regulatory Engineer - Limerick Generating Station

Jecret.try, Nucicar Committee of the Board

Public Document Room (PDR)

Local Public Document Room (LPDR)

Nuclear Safety information Center (NSIC)

NRC Resident Insrector

Commonwealth of Pennsylvania

)

s

(

<

OFFICIAL RECORD COPY

._

.

.

_ _ _ . _ -

._._ .

_ ..__ _.

-

. ,

.

9

j

! biladelphia Electric Company

3

1

bec witsc.ls:

Region 1 Dlcket Room (with concurrences)

,

l

Management Assistant, DRMA (w/o encl)

R. Blough, C?tP

L. Doerflein, Section Chief, DRP

P. Kaufman, DRP

-

M. Conner (SALP i<eports only)

K. Abraham, PAO (20) SALP Report

M. Miller, SLO

J. Caldwell, NRR

R. Clark, NRR

J. Joyner, DRSS

R. McBrearty, DPc

E. Kelly, DRP (see .alion 1.3)

P. Espen, DRS (see k rib.t 1.3)

bec w/ letter and Executive S Froary only:

W. Hehl, DRP

J. Wiggins, DRP

W. Hodges, DRS

J. Durr, DRS

L. Bettenhausen, DRS

M, Knapp, DRSS

J. Lyash, SRI Peach Bottom

B. Norris, PI-Shoreham

W. Butler, NRR

!

I

9

RI:DRP

RI:DSP

RI:DRP

l

C8

ah

l

Kenr

Doerflein

Blough

_

'

=

'11736

1/s/91

1/S/91

L

l

OFFICIAL RECORD COPY

l

I

. . . .

. . .

. .

_

_.

. . - ,

.

_

, _ _

__

. _ . . . . _ . , _

.._. . . - .