ML20028H728

From kanterella
Jump to navigation Jump to search
Forwards Rev 0 to NFU-114, Core Operating Limits Rept,Hope Creek Generating Station,Cycle 4/Reload 3.
ML20028H728
Person / Time
Site: Hope Creek PSEG icon.png
Issue date: 01/24/1991
From: Labruna S
Public Service Enterprise Group
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20028H729 List:
References
NLR-N91012, NUDOCS 9101290267
Download: ML20028H728 (2)


Text

. - . . -. . - . .,, .

g,, ....

Pub!ic Service Electnc and Gas Company

, ' St nit) LaBruna Public Service Electric and Gas Company P.O. Box 236. Hancocks Bridge, NJ 03038 609,339 4800

-- vceom.aen. wow overus JAN 2.41991 HLR-No1012 4

United States Nuclear Regulatory Commission Document Control Desk Washington,-DC 20555 Gentlemen:

TECHNICAL SPECIFICATION 6.9.1.9

. HOPE CREEK GENERATING STATION DOCKET NO. 50-354 Public Service Electric and Gas (PSE&G) hereby submits the Core Operating Limits Report for Hope Creek Cycle 4/ Reload 3 pursuant to the requirements of Technical Specification 6.9.1.9.

In'accordance-with'the Technical Specification, one copy is being sent to the Document Control Desk, one copy is being sent to the Regional Administrator, and-one copy is'being sent to the Resident

? Inspector.

r L Should you have any questions or comments on this submittal, do not hesitate to contact us.

Sincerely, Enclosure g0 9101290267 910124 1 l- PDR ADOCK 05000354 L P PDR W W .l. L ?4

. 1

.,, .** j

. l Document Contro' Desk 2 VAN 2 41991 NLR-N91012 C Mr. Stephen Dembek l Project Manager Mr. T. P. Johnson Senior Resident Inspector Mr. T. Martin, Administrator Region I Mr. Kent Tosch, Chief New Jersey Departn3nt of Environmental Protection Division of Environmental Quality Bureau of Nuclear Engineering CN 415 Trenton, NJ 08625 l