i
[\\FIrh NRC418
=
- U.S. NUCLEAR REGULATORY CoMMISSloN I
,'0 CFR g CERTIFICATE OF COMPLIANCE For Radioactive MIttri;ls Packtges 1.lt) Cer ficate Number 1.(O) Revision No.
1.(c) Pac de t f ion No.
1.(d Pages No. 1.(e) tal No. Pages
- 2. PREAMBLE 2.(a)
This certificate is issued to satisfy Sections 173.393a,173.394,173.395, and 173.396 of the Departrnent of Transportation Hazardous Materials Regulatione (49 CFR 170-189 and 14 CFR 105) and Sections 146-19-10s and 146-19-100 of the Department of -
Transportation Dangercus Cargoes Regulations (46 CFR 146-149), as amended.
2.(b)
The packaging and conterits described in item 5 below, meets the safety standards set forth in Subpart C of Title 10, Cade of Federal Regulations, Part 71," Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions."
2.(c)
This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or into which the package will be transported.
- 3. This certificate is issued on the basis of a safety analysis report of the package design or application-3.(a)
Prepared by (Name and address):
3.lb)
Title and identification of report or application:
Hittman Nuclear & Development Hittman Nuclear & Development Corporation, application Corporation dated April 5,1982, as supplemented.
9190 Red Branch Road Columbia, MD.21045 71-9151 3.(c)
Docket No.
- 4. CONDITIONS This certificate is conditio' sal upon the fulfilling of the requirements of Subpert D of 10 CFR 71, as applicable, and the conditions specified in item 5 below.
l
- 5. D scriptbn of Packaging and Authorized Contents. Model Number, Fissile Class, Other Conditions, and
References:
(a) Packaging (1) t'odel "os. :
HU-100 Series 3 and C"S14-170 Series III l
(2) Description i
A steel encased, lead shielded cask for low specific activity material.
The cask is a right circular cylinder 81-1/2 inches high by 81-3/4 (or 81-1/2) inches in diameter. The cask cavity is 73-3/8 inches high by l
75-1/2 inches in diameter. The cask side wall consists of a 3/8-inch thick inner steel shell, a 1-7/8' (or 1-3/4-) inch lead shell, and a l
7/8-inch thick outer steel shell. The base is comprised of two, 2-inch thick steel plates welded together to form a 4-inch thick base which is integrally welded to the inner and outer steel shells of the side wall. A steel flange is welded to the inner and outer steel shells of the side wall at the top.
The lid is comprised of two, 2-inch thick steel plates, which are stepped and welded together to mate with the steel flange. The cask closure is sealed by a Neoprene gasket located between the lid and steel flange, positive closure of the lid is accomplished by eight (8),1-3/4-inch rachet binders. The lid contains a centrally located shield plug comprised of two, 2-inch thick steel plates.and one,1-inch thick steel plate stepped and wel ded.
The shield plug is sealed by a Neoprene gasket, and eight, 3/4-inch studs and nuts are used to provide positive closure. The packagings are constructed of A-516, Grade 70, carbon steel. The outer shell will have a minimum yield strength of 46,000 psi.
l 8302080445 830112 PDR ADOCK 07109151 C
/ g' i
3 Page 2 - Certificate No. 9151 - Revision flo.1 - Docket No. 71-9151 (2) Description (continued)
Tie-down is accomplished by four tie-down lugs welded to the cask body.
There are four cask lifting lugs, three lid lifting lugs, and one shield plug lifting lug. The pa::kage gross weight is approximately 53,005 pounds.
(3) Drawi ngs The packagings are fabricated in accordance with Hittnan Nuclear &
.l e
Development Corp. Drawing Ilos.:
C001-5-9138, Rev. 6;~ C001-5-9139, Rev. 4; C001-5-9140, Rev. 4; C001-5-9141, Rev. 2; C001-5-9142, Psey. 1; C001-5-9143, Rev. 5; and C001-5-9144, Rev. 3.
The Model No. CNS 14-170. Series III has one or more of the options.
shown in Chem-fluclear: Systems, Inc. Drawing flo..C-110-D-0006, Rev. A.
(b) Contents (1) Type and form of material Greater than Type A quantities of,nonfissile radioactive material.as process solids, either dewatered, solid or solidified,- meeting the n
reouf rements for Icy specific activity radioactive material (10 CFR 571.4(g)),
sealed in secondary containers.
l (2) Maximun quantity of naterial per package.
flot to exceed a decay heat generation of 5 watts, with the weight of the contents, secondary containers, liner, and shoring-not exceeding l
19,205 pounds.
t 6.
Shoring must be placed between secondary containers and the cask cavity to prevent movement during normal conditions of transport.
I
'7.
The lid, shield plug, and cask lifting lugs must be covered in transit to preclude their use as tie-down devices.
8.
In addition to the requirements of Subpart D of 10 CFR Part 71:
(i) Prior to each shipment, the packaging lid seals must be inspected. The seals must be replaced with new seals if inspection shows any defects or every twelve (12) months, whichever occurs first.
(ii) Each package must meet the Acceptance Tests and Maintenance Program of Section 7.0 and Appendix E of the application.
Gamma scan for the shielding acceptance may be bt. sed on-lead equivalence for lead and steel with all readings within 2.3 inches +10% on a 4-inch grid.
.~.
')
y Page 3 - Certificate flo. 9151 - Revision No.1 - Docket Ho. 71-9151 9.
The package authorized by this certificate must be transported on a motor vehicle, railroad car, aircraft, inland watercraft, or hold deck of a seagoing vessel assigned for the sole use of the licensee.
10.
The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR $71.12(b).
11.
Expiration date: June 30,1987.
REFERENCES Hittman Nuclear & Development Corporation application dated April 5,1982.
Supplements dated: April 22 and June 17, 1982.
Chem-Nuclear Systems, Inc. application dated November 16, 1982.
l FOR THE U.S. HUCLEAR REGULATORY COMMISSION f
./
Charles E. MacDonald, Chief Transportation Certification Branch Division of ruel Cycle and liaterial Safety Date:
JW I? 1993 L
1
'1 U.S. Nuclear Regulatory Commission Transportation Certification Branch Approval Record flodel Nos. H'l-100 Series 3 and CNS 14-170 Series III Packagings Docket No. 71-9151 By letter dated November 16, 1982, Chem-Nuclear Systems, Inc. requested certain options to the Model flo. Hi!-100 Series 3 packaging.
The packaging with one or nore of the options shown on Chem-Nuclear Systens, Inc.
Drawi ng No. C-110-0-0006, Rev. A will be designated the Model No. CNS 14-170 Series III Packaging:
1.
Outer cask dianeter 81-1/2 inches rather than 81-3/4 inches. Lead thickness of 1-3/4 inches rather than 1-7/8 inches.
2.
Stainless steel liner constructed of 304SS,12 ga.
3.
Weld specification for joining internal shell to the cask bottom.
4.
Helder qualifications.
5.
Drain line.
The outer shell A-516, Grade 70, carbon steel, yield strength has been reduced froa 49,000 psi to 46,000 psi.
En ottien has been included to permit a shielding canna scan based on lesd equivalence for lead and steel with all readings within 2.3 inches
+10's on a 4-inch grid.
Based on the analyses present by the applicant and judgements made by the staff, it is concluded that none of the changes requested significantly affect the ability of the package to meet the requirements of 10 CFR Part 71.
Charles E. flacDonald, Chief Transportation Certification Branch Divisicn of Fuel Cycle and feterial Safety, NMSS Date:
7 12 383 l
l l
l I
-