Updated LER 81-082/03X-1:on 811231,during Biweekly Control Rod Assembly Partial Movement Test PT-6,rod J-9 Found Inoperable.Caused by Connector Pin in Lift Coil Wiring Not Making Electrical Contact.Pin Adjusted & Rod Tested
ML20028G108
Person / Time
Site: Surry 
Issue date: 01/27/1983
From: Joshua Wilson
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20028G108 (2)
Updated LER 81-054/03X-1:on 810923,higher than Normal Activity Detected in Storm Drain Sys.Caused by Leaking of Four Tubes in HX Bundle of 1-BR-E-10A & Failure of Auxiliary Steam Drain Receiver Pumps to Prevent Overflow
ML20028G105
Person / Time
Site: Surry 
Issue date: 01/27/1983
From: Joshua Wilson
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20028G105 (2)
LER 83-001/03L-0:on 830112,at 100% Power,Radiation Monitor Recorder RR-100 Failed Low.Caused by Insulating Film Buildup on Monitor Selector Contacts.Contacts Cleaned & Recorder Returned to Svc
ML20028G103
Person / Time
Site: Surry 
Issue date: 01/27/1983
From: Joshua Wilson
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20028G103 (2)
Forwards LER 83-001/03L-0 & Updated LERs 81-054/03X-1 & 81-082/03X-1
ML20028G096
Person / Time
Site: Surry 
Issue date: 01/27/1983
From: Joshua Wilson
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20028G096 (1)