ML20028G061

From kanterella
Jump to navigation Jump to search
Forwards LER 83-001/03L-0
Date released: 02/11/2020 Download: ML20028G061


LER 83-001/03L-0:on 830110,pressurizer Code Relief Valve Setpoint Averaged Above Tech Spec Limit During Setpoint Testing.Cause Unknown.Spring Compression Adjusted on Test Stand.Valve Retested & Acceptable Results Obtained
ML20028G063
Person / Time
Site: Arkansas Nuclear 
Issue date: 01/26/1983
From: Rogers P
ARKANSAS POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML20028G063 (1)
Forwards LER 83-001/03L-0
ML20028G060
Person / Time
Site: Arkansas Nuclear 
Issue date: 01/26/1983
From: John Marshall
ARKANSAS POWER & LIGHT CO.
To: SEIDLE W C
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML20028G060 (1)