Form NRCC18 e U.S. NUCLEAR REGULATORY COMMISSION

,fcpg 7, 2 731 CERTIFICATE CF COMPLIANCE For Radioactive Materlats Packages 1.(a) Certificate Number 1.(b) Revision No.

1.(c) Package Identification No.

1.(d) Pages No. 1.(e) Total No. Pages 6188 2

USA /6188/B( )F 1

3

2. PnEAMBLE 2.la)

This certificate is issued to satisfy Sections 173.393a,173.394,173.395, and 173.396 nf the Departrnent of Transportation Hazardous Materials Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amended.

2.(b)

The packaging and contents described in item 5 below, meets the safety standards set forth in Subpart C of Title 10. Code of Federal Regulations. Part 71, Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions."

2.(c)

This certificate does not relieve the consignor from complian'ce with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or into which the package will be transported.

3. This certificate is issued on the basis of a safety analysis report of the package design or application-3.(a)

Prepared by (Name and address):

3.(b)

Title and identification of report or application:

U.S. Department of Energy Safety Analysis Report for 25.0 Spare Division of flaval Reactors Module Shipping Container dated February.6,1969, Washington, D.C.

20545 as supplemented.

3.(c)

Docket No. 71 6188

4. CONDITIONS This certificate is conditional upon the fulfilling of the requirements of Subpart D of 10 CFR 71, as applicable, and the conditions specified in item 5 below.
5. Description of Packaging and Authorized Contents Model Number, Fissile Class, Other Conditions, and

References:

(a) Packaging (1) Model flo.:

25.0 Spare Module (2) Description The container, constructed of 1/8 inch carbon steel plate, is circular in cross section, 40 inches diameter, and approximately 360 inches long.

It has a removable upper half shell employing a stainless steel closure flange with a rubber 0-ring gasket for sealing. The four main handling points of the container are located on the sides at the container base.

Steel skids run the full length of the container.

Each fuel module to be transported is clamped into a renovable trough-shaped strongback which is shock mounted to the interior of the lower shell.

The flanged carbon steel strongback with its stainless steel liner is 323 inches long having holes at regular intervals with stamped station numbers identifying those holes to be used in clanping a particular fuel module.

Each fuel module type has its own clamping arrangement; some claaps will not he in use and are stored within the container. When a fuel module is installed in the sealed container, the container is purged and pressurized with dry nitrogen gas. !1a ximua weight of loaded container is approximately 10,680 lbs.

i

)

$$$*lSoToN0hj C

s.

q Page 2 - Certificate No. 6188 -~ Revision No. 2 - Docket No. 71-6188 (3) Drawings The packaging is constructed in accordance with Westinghouse Electric Corporation Drawings llos. 901E851, Rev.1, Sheet.1 thru 9 of 9 and

' 901E440, Rev. 2, Sheet 1 thru 9 of 9.

(b) Contents (1) Type and form of material Unirradiated fuel assemblies of the following type, (i) AlW-3 new fuel module with control rod and upper control rod drive nechanism installed.

(ii) Partial A1W-3 new fuel module with poison rods as shown on Westinghouse Electric Corporation Drawing flo. 927J942, Rev.1 and poison rod lock-in device as shown on Westinghouse Electric Corporation Drawing No. 938F030, Rev. 2.

(2) Maximum quantity of material 'per package.

(i) One fuel assembly as described in 5(b)(1)(i).

(ii) Two fuel assemblies as described in 5(b)(1)(ii).

(c) Fissile Class III Maximum number of packages per shipment:

9 6.

Expiration date: January 31, 1988.

REFEREHCES Safety Analysis Report for 25.0 Spare tbdule Shipping Container, WAPD-0P(R)SS-ll56 dated February 6,1969.

l l

l O

Pag? 3 - Certificate No. 6188 - Revision No. 2 - Docket No. 71-6188 Supplements: ' Bettis Atomic Power Laboratory letters WAPD-0P(R)SS-1107 dated October 21,1968, WAPD-0P(R)SS-1333 dated July 3,1969 and WAPD-0P(R)SS-1530 dated December 10, 1969.

l FOR THE U.S. NUCLEAR REGULATORY COMMISSION 0

Charles E. MacDonald, Chief.

Transportation Certification Branch Division of Fuel Cycle and Material Safety JgU 0 4 @

Date:

e 9

0

w U.S. Nuclear Regulatory Commission Transportation Cert 1Tication Branch Approval Record Model Ho. 25.0 Spare Ibdule Packaging Docket t!o. 71-6 TIT 8 By application dated July 27, 1982, U.S. Department of Energy requested renewal ^of Certificate of Compliance No. 6188.

flo changes have been authorized to the package design since approval of latest supplement dated December 10, 1969.

The staff concludes that the statements of the original application, as supplenented, satisfies the requircaent for renewal of -the Certificate of Compliance.

--k Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety, tr4SS 0 G M3 Date: