Forwards Request for Addl Info Required to Complete Review of 820716 Revised Chapter 5 to Fundamental Nuclear Matl Control Plan
ML20028C013
Person / Time
Site: 07001201
Issue date: 08/31/1982
From: Evans L
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Jennifer Ford
BABCOCK & WILCOX CO.
References
NUDOCS 8301050235
Download: ML20028C013 (2)


Text

,

_ - ~

" Return to SGFF/ MSS Mail Stop 881-SS" DISTRIBUTION:

PDR Docket file-70-1201 Case file MSS r/f SGFF r/f s/f.

AUG 31 19$

CRON0 MCL r/f CNSmith H artz SGFF:H8 70-1201

, IE RPage, FC EMcAlpine, RII Babcock and il11cox Campany Connercial Nuclear Fuel Plant ATTN: Mr. J. T. Ford License Administrator P. O. Box 800 Lynchburg, Virginia 24505 Gentlemen:

This is in response to your letter dated Asly 16, 1982 which transmitted a revised Chapter 5 to your Fundamental Nuclear Material Control Plan.

Our review has identified several areas of your revised plan which require additional infomation. The enclosure to this letter describes these items which nust be addressed in order to complete our review.

It has been established that the enclosure to your letter dated July 16, 1982 coratains infomation of a type specified in 10 CFR 2.790(d). Accordingly, pursuant to Section 2.790(d)(1), such information is deemed to be caneercial or financial information within the meaning of 10 CFR 9.5(a)(4) and shall be subject to disclosure only in accordance with the provisions of 10 CFR 9.12.

Sincerely.

OriginalEigned By*-

l L.J. Evans,1r.

L. J. Evans, Jr., Chief Fuel Facility Safeguards Licensing Branch Division of Safeguards NMSS

Enclosure:

As stated I

1 8301050235 820031 PDR ADOCK 07001201 grfggjp0/loaoM f C

PDR l

- "o >......SGFf g,..S ed hh

~+ HBartzah,.

.CN.

""> 8/.S 7.82.....8/.2. 82....... a6\\./82.......

""C ?"?8!8"t8 M"CS!?'.. _. _.., _ _ __. OFFICI AL RECORD. COP.Y______ _

ENCLOSURE BABC0CK AND WILCOX COMPANY COMMERCIAL NUCLEAR FUEL PLANT 70-1201 1.

Page 5.6, item 5.4.1.2 - Fuel rods in channels a.

Are 100% of serial numbers checked to prelist?

b.

What activity will B&W follow to verify those fuel rods that have been transferred in or out of the area between the time of the prelist and the actual physical inventory?

2.

Page 5.7, item 5.4.2.2 - Tampersafed items, last sentence.

"If a tamperseal cannot be verified in this manner, the item quantity may be verified by check weighing."

a.

Can check weighing alone be adequate for all forms of SNM7 b.

What are accept / reject limits for weight?

The additional information may be incorporated on the same pages or may be incorporated by reference to other procedures.

l