Forwards LER 82-029/03L-0.Detailed Event Analysis Encl
Date released: 02/11/2020 Download: ML20028B734


LER 82-029/03L-0:on 821025,during Zero Power Testing, Isolation Amplifier Resistor Input on Power Range Channel NI-44 Found Out of Calibr Tolerance.Caused by Instrument Drift.Channel Removed from Svc & Calibr
ML20028B746
Person / Time
Site: Summer 
Issue date: 11/23/1982
From: Mckinney C
SOUTH CAROLINA ELECTRIC & GAS CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20028B746 (1)
Forwards LER 82-029/03L-0.Detailed Event Analysis Encl
ML20028B733
Person / Time
Site: Summer 
Issue date: 11/23/1982
From: Dixon O
SOUTH CAROLINA ELECTRIC & GAS CO.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20028B733 (2)