O GINNA STAT!ON U."7.": 1 C ^. ' :::. IT D

{

B0CHESTER GAS AND ELECTRIC 00FPORATION DAIE -

i GINNA STATION TIME :-

CONIPOLLED COPY NLMBER PROCEDURE NO.

SC-410 REV. NO.

4 INSPECTION OF EMERGENCY EQUIPMENP TBCHNICAL Ps'NIEW PORC REVIEW DA'IE \\C

~

li QC REVIEW PLANT SUPERINIEtCENP V

i t sO-t f51 i

EFFECTIVE DATE QA X

NON-QA CATEGORY 1.0 REVIEWED BY:

'DiIS PROCEDURE CONTAINS 12 PAGES 1

l 8211160480 921108 PDR ADOC),$000244 F

PDR

o SC-410:1 SC-410, INSPECTION OF EMERGENCY EQUIPMENP

1.0 PURPOSE

1.1

'Ihe equipment required by the energency plan and the means of assuring it is available is outlined in this procedure.

Inspections will be made nonthly as required by Tedinical Specifications and after each drill or use.

2.0 REFERENCES

2.1 SC-1, Dnergency Plan 2.2 Tech. Specs., Table 4.1-1

3.0 INSTRUCPIONS

3.1 Inspect each location using attached appendixes. Indicate ntanber of items present in blank space on appendix.

3.1.1 Emergency Survey Center - Appendix A 3.1.2 Control Iban - Appendix B 3.1.3 Health Physics Office, Auxiliary Building, Operational Support Center - Appendix C 3.1.4 Technical Support Center - Appendix D 3.1.5 Monthly Inspection tog - Appendix E 3.2 If any discrepancies are found make note on the Monthly Inspection tog (Appendix E).

If there are no discrepencies, enter NONE on tog Sheet.

3.2.1 Discrepancies are to be corrected (or a trouble card submitted) as soon as possible and so noted on the log sheet and filed per A-1701.

3.3 Perform nonthly cperational check with check source on Dnergency Plant Vent Konitor (Radector III). Record discrepancies on ibnthly Inspection 103 - Appendix E and advise Health Physicist.

SC-410:2 APPENDIX "A" ENERGENCY EQUIPMENT IN SURVEY CENTER 1.

Assignment tag board - all tags in place 2.

Survey team maps - Red, Green, Orange, Blue, Yellow 15 3.

Survey team boxes - Red, Green, Orange, Blue, Yellow, white - If seal is unbroken assume equipment is intact.

Inventory boxes and dange batteries in January and July. 6 4.

Beta - Gamma survey instruments - battery check, source check. Assure calibration and efficiency calibrations are within a six month period.

5 5.

High level dose rate meters - battery check, source check, calibration deck.

6 6.

Extendable high level survey meter - battery check, source check, calibration check.

1_

7.

Nucleus scaler with probe and count shelf-frequency check, source check, efficiency calibration semi-annually.1 8.

Radiation nonitor RM-3C or equivalent, with HP-260 probe equivalent, battery check, source check, calibration check.

1 9.

Area radiation nonitor, stationary - change chart paper, operational check.

1

10. Dosimeter charger with battery 2
11. Dosimeter (High Range) - check calibration 0-5R 8

0-10R 8

12. Dosimeter (0-500mr) - check calibration 12
13. %ermal luminesent dosimeters 10
14. Packages of (6) enviromental TLD badges (off-site only) 3
15. Battery operated, low volume air samplers - calibration check, Run air sampler several minutes to check operation, semi annually totally discharge and recharge saplers (February and August) 6
16. Battery charger - operation check, disconnect 1

SC-410:3 APPENDIX "A" (cont.)

17. RADECO 11809 B2 air sampler - run 120 minutes 2
18. RADECO H 809 C air sampler - run 1 minute 4
19. Filters for air samplers particulate
20. Filters for air samplers - silver zeolite
21. Envelopes for air samples particulate 100
22. Envelopes for air samples - iodine 100
23. Envelopes for smear papers 100
24. Smear pap,*rs 1000
25. Decontamination kit 1
26. Radios, portable - radio check with security 6
27. Magnetic car mount antenna 3
28. Radio, stationary - radio check with security - log book entry.

1

29. Full face respirator with charcoal filter - inspect mask, mark bag with inspection date and initials, check filter expiration date 22
30. Voice emitters for respirators - operational check 13
31. Contaminated clothing & waste containers, 55 gal drum 2~-
32. Anti - contamination clothing, sets 25-
33. Step off pads 10-
34. Tape, rolls IBOX
35. Plastic bags, poultry IBOX
36. Plastic bags, clean, large 20'
36. Radioactive material bags, yellow, large 1 Roll
37. Radiation rope 1 Roll-
38. Radiation hazard signs with inserts 10

SC-610:6

39. Thyroid block tablets, bottles 25
40. Pens and pencils 10
41. Batteries, D size 10
42. Extension cord 3
43. Intercom "A" - communication check with Control Room.

Call Control Room on GAI page, have them plug in Intercom A and contact survey center 1

44. NRC Red telephone - Lift receiver, tell party "This is a Ginna Station Survey Center Communications Check".

1

45. New York State Red telephone - Push button, lift receiver wait 10 seconds, ask if New York State, Wayne County, Monroe County are listening? Tell them "This is Ginna Station Survey Center Communications Check".

I

46. Telephone books - Rochester 1, Wayne County 1 1
46. Telephone communications link check - call
47. Wayne County M 1,
48. Monroe County M 1
49. New York State M 1
50. National Weather Service, Rochester M 1
51. National Weather Service Buffalo ( N 1

5?. FromM call Control Rocra at Mand TSC at M 1

53. From extension S call TSC at M 1
54. From extension M all TSC at M 1
55. From extension M call ESC at W l

Initials Date

SC-410:5 APPENDIX "A" (continued)

EMERGENCY EQUIPMENT PER SURVEY BOX If box is sealed inventory not required. Boxes shall be opened in January and July for battery change and inventory.

1.

Coveralls 2

2.

Hoods, disposable 2

3.

Gloves, pair 2

4 Booties, pair 2

5.

Hats, Surgeon 2

6.

Hoods, Rain 2

7.

Coats, Rain 2

8.

Boots, Rain, pair 2

9.

Suits, cold weather (carhart) 2

10. Equipment Belts with Bags (On-Site team only) 2
11. Flashlight with Batteries 1
12. Plastic Bags 2
13. Masking Tape, rolls 2
14. Pencils 2
15. Pencil Sharpener 1
16. Tablet, writing 1
17. Survey Route Maps 2,,,
18. Air Sampler Filters - Particulate 5
19. Air Sampler Filters - Silver Zeolite GY-130 5
20. Air Sample Envelopes (Iodine) 10
21. Air Sample Envelopes (Environmental) 10

SC-41036 APPE:NDIX "A" cont.

22. Dimes for 'Delephones (Off-site tem only) 10
23. Clipboard 1
24. Appropriate procedure for tean (Remove survey route instructions in Appendix III that do not apply to that survey te m)
25. Procedure SC-452, Sanpling Snow, Grass, Soil, and Vegetation.
26. Haruner and 10 nails (off-site caly) 1
27. '1hyroid Block tablets (bottle) 3
28. HP-190 window clamp (off-site tems only) 1
29. First Aid Roan key (on-site teau only)
30. Backpacks - 2 (on-site teams only)

Initials Date

~

l

SC-410:7 APPENDIX "B" EMERGENCY EQUIPMENT IN CONTROL ROOM 1.

Scott Air Pack (SCBA) - monthly inspection 2'

2.

High range dosimeters - calibration check 10 3.

Dosimeter charger with battery - operability check 1

4.

High range dose rate meter - battery check, source check calibration check 1

5.

Plant radiation survey maps (sets) 3 6.

Smear papers 100 7.

Envelopes for smear papers 10 8.

Thyroid block tablets (bottle) 1 9.

Air sampler, low volume - operability check, calibration check 1

10. Air sampler filters particulate 3
11. Air sampler filters - silver zeolite 3
12. Radiation monitor RM-14 or equivalent with HP-190 probe 1
13. Tape, roll 1
14. Anti-contamination clothing (sets) 6 Initial Date

SC-410:8 APPENDIX "C" De3GENCY EQUIPMDTP OPERATIOtRL SUPPORT CEtifER 1.

Fill face respirators - inspect mask and mask bag with inspection date and initials 6

2.

Respirator charcoal filters - expiration date 6

3.

Anti-contamination clothing (sets) 6 4.

Flood lights, portable - operational check 2

5.

'Ihyroid block tablets (bottles) 15 6.

Dosimeters 0-500 mrem - check calibration 10 7.

Dosimeters 0-10R - check calibration 10 8.

Dosimeter charger with battery - operational check 1

S.

Daily exposure record sheets 5

10. Pens 5

AUXILIARY BUILDING 1.

Scott air pack (SCBA) - monthly inspection 1

2.

High range dose rate meter - battery check, source check, calibration check 1

HEAUIH PHYSICS OFFICE 1.

Scott air pack (SCBA) - monthly inspection 5

2.

High range dosimeter - calibration check 20 3.

Anti-contamination clothirg (sets) 20 4.

High range dose rate meter - battery dieck, source check, check calibration 5

Initials Date

SC-410:9 APPENDIX D EMEIGENCY EQUIPMENP IN TECHNICAL SUPPORP CDi1ER 1.

Radiation monitor BM-14 or equivalent with HP-190 probe battery deck, source check, check calibration 1

2.

Area radiation monitor - battery deck, source deck, check calibration 1

3.

Eb11 face respirator - inspect mask mark bag with inspection date and initials 10 4.

Respirator charcoal filter - check expiration date 10 5.

'Ihyroid block tablets (bottles) deck expiration date 25 6.

Dosimeter, 500mr - check calibration 25 7.

Dosimeter, high range - 6eck calibration 10 8.

Dosimeter charger with battery - operability deck 1

9.

RADECO H-809 B2 air ranpler - run 120 minutes 1

10. Air sample filters - particulate 4
11. Air sample filters-silver zeolite 4
12. Anti-contamination clothing (sets) 25
13. Step Off Pads 10
14. Daily exposure records sheets 5
15. Radioactive materials bags (yellow) 5
16. Tape, rolls 5
17. Smear papers 100
18. Envelopes for smears 10
19. Envelopes for particulate air sanpleg 10 it
20. Envelopes for iodine air samples

?

10 r

~

SC-410:10 APPENDIX D cont.

21. Pens and pencils Sea
22. Radio, Pt,rtable - radio check with security 4
23. Radio, Stationary - radio check with security - log book entry 1
24. NRC Red telephone - lift receiver, tell party "@is is a Ginna Station TSC Ccmrunication Geck".
25. New York State Red telephone - push button, lift receiver, wait 10 seconds, ask if New York State, Wayne Cbunty, Monroe County are listening? Tell then "@is is Ginna Station TSC Comnunication Geck".
26. HPN telephone-dial selected station to confim cmmunication deck 1
27. EOF Direct line M Telephone 1
28. Plant process ocxnputer and silent 700 operational check.

-1 Initials Date

SC-410:11 APPENDIX "E" EMERGENCY EQUIPMENT MQmiLY INSPECTIOi IOG DISCREPANCIES NOTED DISCREPANCIES CORRECTED Survey Center Date Initials Date Initials Control Room Date Initials Date Initials HP Office Date Initials _

Date Initials Auxiliary Building Date Initials Date Initials Technical Support Center Date Initials Date Initials 1

Operational Support Center Date Initials Date Initials i

Dnettjency Plant Vent Monitor Date Initials Date Initials REVIEMED BY:

SC-410:12 o

LIST DISCREPANCIES AND/OR CORRECTIONS:

l I

h l

1