Forwards LER 82-042/01T-0
Date released: 02/11/2020 Download: ML20028A105


LER 82-042/01T-0:on 821027,excessive Water Found Leaking from Recirculation Pump Seal 3B.Caused by Recirculation Pump Seal Failure.Unit Manually Brought Down.Seals Replaced. Supplementary LER to Be Issued When Cause of Failure Known
ML20028A116
Person / Time
Site: Dresden Constellation icon.png
Issue date: 11/09/1982
From: Morgan W
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML20028A116 (3)
Forwards LER 82-042/01T-0
ML20028A104
Person / Time
Site: Dresden Constellation icon.png
Issue date: 11/09/1982
From: Scott D
COMMONWEALTH EDISON CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML20028A104 (1)