Forwards LER 82-067/03L-0
Date released: 02/10/2020 Download: ML20027D872


LER 82-067/03L-0:on 821017,steam Generator C Narrow Range Channel 2 (LI-2495) Indicated High.Caused by Failure of Transmitter Amplifier Card.Card Replaced & Loop Recalibr