P 1

BALTIMORE GAS AND ELECTRIC CHARLES CENTER. P.O. BOX 1475 BALTIMORE, MARYLAND 21203 ELKcTRtc ENGINEERING oKPARTMENT October 12,1982 Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Attn:

Mr. Robert A. Clark, Chief Operating Reactors Branch #3 Division of Licensing

Subject:

Calvert Cliffs Nuclear Power Plant Units Nos.1 & 2; Dockets Nos. 50-317 and 50-318 Post-TMI Requirements

References:

(a) Letter from A. E. Lundvall, Jr. to D. G. Eisenhut, dated 4/19/82 (b) Letter from A. E. Lundvall, Jr. to D. G. Eisenhut, dated 6/4/82 Gentlemen:

In Generic Letters 82-05 and 82-10 dated March 17, 1982 and May 5,1982, respectively, the NRC forwarded to all holders of operating reactor licensees a list of proposed completion dates for selected TMI-related items. In these letters the NRC also requested that all licensees provide justification and detailed schedule information for those items that would not be completed by the proposed dates. Accordingly, we provided the desired information in References (a) and (b). The purpose of this letter is to provide you with an update of our progress in closing out these TMI-related actions.

With the exception of four items, all of the action items we had discussed in References (a) and (b) have been completed. Our progress (or position) on these items is reiterated below for your information.

I.C.I

- Revise Emergency Procedures We refer you to our letter from Mr. ', E. Lundvali to Mr. D. G.

Eisenhut, dated August 31, 1982, wh;cn forwarded our position on this issue.

II.F.I.(2)

- Noble Gas Steam Effluent Monitor l

Installation of a reliable system contin 0es to be a problem. As discussed with you earlier, we expect to have an operational system installed in Unit I no later than June 1,1983. Sufficient progress in acceptability testing is being demonstrated by the vendor such that shipment from the factory may be possible by-the end of October or in November of this year. Given delivery to 8210180005 821012 pf(p PDR ADOCK 05000317 P

PDR

o Mr. R. A. Clark October 12,1982 the plant next month, we will make a good-faith effort to install a system in Unit 2 during the upcoming fall outage. Nevertheless, it is not unreasonable to expect that delivery, installation and testing problems may develop which will delay operability until some date after the Unit 2 outage. Therefore, we propose that the completion date for Unit 2 be made common with that of Unit 1; i.e., June 1,1983, to allow sufficient margin to deal with such problems.

II.F.1.(5)

- Containment Water level Monitor This item had been initially considered complete; however, a deficiency was found after an initial period of successful operation (see our letter to R. A. Clark, dated January 19, 1982).

Installation of an instrument of improved design in Unit I has been completed. Installation in Unit 2 will be completed during the upcoming fall outage.

III.A. I.2

- Upgrade Emergency Support Facilities Our Emergency Operations Facilit, (EOF) is still scheduled to be completed by the end of 1983. Our Interim EOF continues to perform those functions necessary to implement our Response Plan.

If you should have any further questions concerning these matters, please contact us.

BALTIMORE GAS & ELECTRIC COMPANY

/

(

L By:

A. E.

dyr.il, r.

Vitu." resident - Supply STATE OF MARYLAND :

TO WIT:

CITY OF BALTIMORE Arthur E. Lundvall, Jr., being duly sworn, states that he is Vice President of the 1

Baltimore Gas and Electric Company, a Corporation of the State of Maryland; that he executed the foregoing for the Purposes therein set forth; that the statements made therein are true and correct to the best of his knowledge, information, and belief; and that he was authorized to execute the same on behalf of said Corporation.

WITNESS My Hand and Notaria! Seal:

b ~ e/bl Notary Public My Commission Expires:

<ff6

' Date

o

' Mr. R. A. Clark -

October 12,1982 AEL/BSM/gyg cc:

3. A. Biddison, Jr., Esquire
G. F. Trowbridge, Esquire Mr. D. H. Jaffe - NRC j

Mr. R. E. Architzel - NRC t

4

~

i i

4 i

a 5

l 4

-I 6

i a

i-f I

i l

D