Text

_ _ _ _ _

e APPENDIX A NOTICE OF VIOLATION Rochester Gas and Electric Docket / License No. 50-244/0PR-18 Corporation During inspection on August 1-31, 1982 and in accordance with NRC Enforcement Policy, 10 CFR 2, Appendix C (47FR9987), March 9,1982, the following violation was identified.

Technical Specification 3.14.1 requires that with the fire detection instruments specified in Table 3.14-1 inoperable for greater than fourteen days, a Thirty Day Written Report shall be submitted outlining the cause of the inoperability and plan for restoring the instruments to operable status.

Contrary to the above, as of August 31,1982, a Thirty Day Written Report had not been submitted documenting that several fire detection instruments specified in Table 3.14.1 had been declared inoperable on July 12, 1982, due to exceeding the surveillance testing frequency, and had not been returned to operable status within fourteen days.

ThisisaSeverityLevelVViolation(Supplement 1).

Pursuant to the provisions of 10 CFR 2.201, Rochester Gas and Electric Corporation is hereby required to submit to this office within thirty days of the date of this Notice, a written statement or explanation in reply including the corrective steps which have been taken and results achieved; corrective steps which will be taken to avoid further violations; and the date when full compliance will be achieved. Where good cause is shown, consideration will be given to extending your response time.

8209300304 820914 PDR ADOCK 05000244 G