ML20027A970

From kanterella
Jump to navigation Jump to search
Forwards LER 82-089/01T-0.Detailed Event Analysis Encl
Date released: 02/10/2020 Download: ML20027A970


LER 82-089/01T-0:on 820830,operator Discovered Svc Water Leak from Containment Fan Coil Unit 23.Caused by Failure of Belzona Repair Made to Coil.Leaking Coil Blanked Off & Unit Tested Satisfactorily.Coils Will Be Replaced
ML20027B028
Person / Time
Site: Salem PSEG icon.png
Issue date: 09/03/1982
From: Heller R
Public Service Enterprise Group
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML20027B028 (1)
Forwards LER 82-089/01T-0.Detailed Event Analysis Encl
ML20027A969
Person / Time
Site: Salem PSEG icon.png
Issue date: 09/03/1982
From: Midura H
Public Service Enterprise Group
To: HAYNES R C
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML20027A969 (4)