l,'l

's ah y,,, y n

~~

~ ^ ^

?

^

~

~

~

?

O O

'NSP mc r

NORTHERN STATES POWER C0MPANY M I N N EC A P O L. l e. M I N N E S O T A 9940t Q) v.

y'

.s-

.s

,V J*I Y E'U }l >\\ M.y)

January 12, 1973

\\

~b 3 **' A.

a a

d/J M -

  • [ #

Mr. Donald J. Skovholt

'y

~ l' '

Assistant Director for Operating Reactors

'M b

WT,N.

//

b M

Directorate of Licensing United States Atomic Energy Commission 7, g',

Washington, D. C.

20545

Dear Mr. Skovholt:

MONTICELLO NUCLEAR GENERATING PLANT Docket No. 50-263 License No. DPR-22 Information Relating to Torus Ring Header Supports Your letter of December 13, 1972, requested five pieces of information concerning the adequacy of tne Monticello torus ring header support design.

In the event the specified information could not be obtained within 30 days, a schedule for sub-mitting it to the Commission was to be provided.

Requested items 1, 2, and 3 will be available in March, 1973 when analyses being conducted by the General Electric Company are scheduled to be completed.

A reply will be prepared, including Items 4 and 5, following completion of this investi-gation.

The General Electric investigation is based on testing conducted in October, 1972 at the Quad Cities Plant.

It is intended that conclusions will be reported on a generic basis.

Results obtained to date indicate that there is no reason for concern over the design of the Monticello ring header.

Indications of possible design deficiencies which may arise during the course of the investigation will be immediately made known to the Commission and the utilities involved.

Further-more, it is our understanding that members of the AEC staff have reviewed the status of this program and the content of the projected report.

Our own experience has indicated that the most likely source of prob 1ces experienced 1

with torus ring header supports is improper fabrication and installation.

As reported to the Directorate of Regulatory operations, Region III, by letters of July 5, 1972, and December 6, 1972, the following repairs were necessary at Monti-cello to correct installatien deficiencies in the system:

1.

l'rgraded, fully threaded bolts were replaced with l

ASME Grade A325 bolts with no threads in the load l

bearing region.

Bolts were fitted with locking l

nuts.

I t

l 5

'4 9102120644 $$$6a I

PDR ADOCK PDR P

, i. ;; r,y~ ~, ync l

/

o Mr. Donald J. Skovholt 2

January 12, 1973 2.

All torch-cut bolt holes were filled and repinced with L

drilled holes.

I 3.

Torus butt plates and padeyes were welded all around with 1/4-inch f111et.

4.

All hanger velds were subjected to magnetic particle inspection.

5.

Static load analysis was conducted and all hanger loads were balmiced.

I These repairs restored the torus ring header support system to original design I

conditions.

In addition, the substitution of the higher strength bolt (original design bolt was ASME Grade A307) has resulted in a substantial upgrading of the ability of the system to withstand dynamic leading.

Yours very truly.

ha L. O. Mayer, p.E.

Director of Nuclear Support Services LJM/DMM/vm cc B. H. Grier i

I x.____._

AEC DIC"ZGTIO:t FOR TATC 50 DDC)CT !&TT".J.S

.e., (Ta'.PoivdiY 70;iM)

C0;iTROL ;io:

50-263 t

~

FIII FiiCM: Northern States Power Co.

DAT2, OF DOC:

DAT4 JWC'D U6';t i'.rJ.J HPi' vi m Minnsspolis, Minn. 55401 1 12-73 1-15-73 X

59:

URIG CJ w'auit a a AEC PDt

/

SE C LOCAL PLa /

.hr. Donald J. Skovholt i signed 39 CMSS:

, Q3t'it0F INio IliNi' iiO GYU AGu'D M E*'ist 40 50-263 DESCalP210;is Ltr re our 12-13-72 ltr...

E;iCI,0s;. Tid;S:

furnishing info relating to torus ring header supp:rts re Monticello Plant.....

  • PLEASE CIRCULATE-INSUFFICIEttr CYS FOR idLL DISTRIBUTION h nU t t fg 1* p f?"

M M iU u.,. ', w p g;;7 m 33:

Monticello Plant

]

",(

'~

us..... w... w,l L

~

FOR ACi'IG;i/ ;;,7u.W./C;0;;

DL l-15-/3 DUTIIR(L)

SCL'E iCER(L)

SCHE ZL(L) 137ICl!?O!!(E)

W/ Copico W/ Copies W/ Copico W/ Copies CIAEK(L)

STOI"(L) dirt /Jil;(L)

YOUNGDEOD(E)

W/ Ccpico W/ Copies W/6Copico W/ Copics GOIl.ER(L)

VASSALw(L)

CHIT *.T.OD(12 )

REGAN(E)

V/ Copico W/ Copics W/ Conica W/ Corice

}3TIEp(L)

H. DI;ITION DICl33d E)

'J/ Cepito

"/ Cerier U/ Cepieu W/ Oqica I:'rEPJ:AL DICTRTE7rION dam FTD TECH REVIL'd VOLUIR H/GJ205 WADE E

C PDR ELid; DE ' ION SHAFER F tc M C, ROO!' P-506A "CHROEDER GRI!IS F te M ERCVN E

DifJITI?.I::G/ STAFF AACCARY G/J0GLL ETYCh' G. WILLIN S E CASE L/d;3E(2)

KAST:!ER liUSSEAU'IR E. GOULIOURNE L NI/JtEUSSO PAVLICEI BALLED A/TIND dOYD-L(%"4)

SHA0 SP/J:3LER LIC /sSST.

EAIT:!/Ji DEYOU'!3-L( F'Jt )

g3VIH EENA7.

S AI!r;"'./di

$KOVHOLT-L STELID DiVIRO

!!ALON L

P. COLLI!T3 IDORE MJL11h VIIE.CN L

FL/J:S

'DUSTON DICKER

}:/dCTJ7T L ET, EALD Fla OFR 2.ESCO E?iIGIT20N S!GTH L

DUEE

/i112 h REGIO:i (2)

ION 3 YCU:;3EID0D GEARIN L

IDFRIS L/JNAS ITiOJ ILJI:R DIGG3 L

II'?O

/STELLE ECIAROYA TEUI'S L

C. ICLE3 U

b E C/Ji DP'M T. DT CTT3 N n" d-IDCAL FDR, Minneapolis. Minn.

d-IllIE( ABERHATHY )

(1)(5)(9)-!!/CIONAL IAB'S 1-FDR-SAN /IA/!!Y d-USIC(EUCH/J:!di) 1-R. CARROLL-0C, GT-E227 1-GERALD IILIDUCHE 1 ASL3-YCRE/SAYRE l-R. CATLI'!, E -F' G -GT ER00}31AVEN NAT. LAB ODWARD/H. ST.

kO 1-CONSUL /JTI'S 1-AG:5D(UALTER MOECTER, 16 CYS ACES XXLD(%n SENT TO LIC. ASST.

NEW:.'AM:/EUIT/AGAEIAN Rn C h27, CT)

R. DIGGS ON 1-15-73 1-RD...MULTM1...F-3390T w_

-