1 f

Appendix A NOTICE OF VIOLATION Northern States Power Docket No. 50-263 Company Based on the inspection conducted on September 26-30, 197 7, i t appears that certain of your activities were t.ot conducted in full compliance with NRC regulations as indicated belos. The following item fs t.n infraction.

Contrary to Technical Specifications 6.5 and 6.5.C.3 and Section IV.A of your procedure, NSP-PT-1, liquid penetrant testing was performed on control rod drive collets between September 14 and 22, 1977, by a noncertified technician.

(

l l

(

9102120599 771014 PDR ADOCK 03000263 PDR G

.... -