ML20024G439

From kanterella
Jump to navigation Jump to search
Forwards Application for Amend to License DPR-22,changing Tech Specs to Reflect Adoption of Getab/Gexl Heat Flux Correlation in Place of Current Hench-Levy Correlation
Date released: 02/07/2020 Download: ML20024G439


Proposed Tech Specs Reflecting Adoption of Getab/Gexl Heat Flux Correlation in Place of Current Hench-Levy Correlation
ML20024G442
Person / Time
Site: Monticello 
Issue date: 03/12/1975
From:
NORTHERN STATES POWER CO.
To:
References
Download: ML20024G442 (25)
Application for Amend to License DPR-22,changing Tech Specs to Reflect Adoption of Getab/Gexl Heat Flux Correlation in Place of Current Hench-Levy Correlation
ML20024G441
Person / Time
Site: Monticello 
Issue date: 03/12/1975
From: Wachter L
NORTHERN STATES POWER CO.
To:
References
Download: ML20024G441 (5)
Forwards Application for Amend to License DPR-22,changing Tech Specs to Reflect Adoption of Getab/Gexl Heat Flux Correlation in Place of Current Hench-Levy Correlation
ML20024G438
Person / Time
Site: Monticello 
Issue date: 03/12/1975
From: Mayer L
NORTHERN STATES POWER CO.
To: GIAMBUSSO A
Office of Nuclear Reactor Regulation
References
Download: ML20024G438 (1)