Responds to NRC Re Violations Noted in IE Insp Rept.Corrective Actions:New Roping Eyelets Placed in Vicinity of Beam Tube to Allow Easy Placement of Ropes & Extra Portable Sign Provided to Allow Posting to Be Visible
ML20024F100
Person / Time
Site: General Atomics
Issue date: 05/25/1983
From: Mowry W
GENERAL ATOMICS (FORMERLY GA TECHNOLOGIES, INC./GENER
To: Crews J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
Shared Package
ML20024F043 List:
References
67-4083, NUDOCS 8309080231
Download: ML20024F100 (1)


Text

p

.:- - u,

n..

.._-_,w E83 N 27 MI 12: 9e Refer To: 67-4083 25 May 1983 GA Technologies Inc.

po sox w

'ft.o g SAN DtEGO. CAUpORNI A 92138 va (619) 455-3000

- !!Y

Mr. J. L. Crews, Director Division of Reactor Projects Nuclear Regulatory Commission, Reg. V 1450 Maria Lane, Suite 210 Walnut Creek, CA 94596

Subject:

Docket 50-163; R-67: Response to Item of Non-Compliance.

Reference:

(a) NRC Region V ltr dtd 4/25/83

Dear Mr. Crews:

This is in response to an April 4-8, 1983, inspection by your staff and your letter, ref. (a), which contains a notice of violation. The notice of violation requires certain responses. They appear below.

The deficiency in posting a high radiation area which was the subject of the Severity V citation has been remedied by the following steps:

1.

Requirements for posting suen areas have been reviewed with the facility staff and the importance of providing markings read-able from both sides of the affected area has been stressed.

2.

New roping eyelets have been placed in the vicinity of the beam tube to allow easy placement of ropes. High radiation area signs are available for use with the ropes.

3 An extra portable sign has been provided to allow posting to be visible from either of the entrances to the reactor room.

4.

The facility staff has been instructed to check radiation levels and marking of areas each time the Mk F reactor is oper-ated with the beam tube assembly in place or with any other ar-rangement which could result in a high radiation area.

The steps described above were completed by May 10 and we feel they will prevent a recurrence of the posting deficiency.

Should you have any comments about the above, please don't hesitate to contact me.

Very truly yours, William R. Mowry Licensing Administrator WRH:he 9309080231 830901 PDR ADOCK 05000163 G

PDR N.