ML20024E979

From kanterella
Jump to navigation Jump to search
Informs That Final Deficiency Rept 83 Re Heat Tracing Design Defects Identified During Hot Functional Testing Will Be Submitted by 840106,rather than 830826 as Previously Indicated
ML20024E979
Person / Time
Site: Waterford Entergy icon.png
Issue date: 08/29/1983
From: Drummond F
LOUISIANA POWER & LIGHT CO.
To: Jay Collins
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
W3183-0291, W3183-291, NUDOCS 8309080058
Download: ML20024E979 (1)


Text

LOUISIANA P O W E R & LI G H T! P O BOX 6008 *

,42 o nAnoNot sineer (504) 366-2345 NEW ORLEANS. LOUISIANA 70174

'$ uS $ EsS $

u August 29, 1983 W3183-0291 Q-3-A35.07.83 Mr. Joun T, Collins Q ]g If 7 ?

Regional Administrator, Region IV 4

U. S. Nuclear Regulatory Commission 9

p$ 3 f,) @

611 Ryan Plaza Drive, Suite 1000 d

1 f

Arlington, Texas 76012 U-SUBJECT? Waterford SES Unit No. 3 Docket No. 50-382

~~

"~

Significant Construction Deficiency No. 83

" Heat Tracing Design Deficiencies Identified.

Luring Hot Functional Testing" Second Interim Report

REFERENCE:

LP&L Letter W3I83-0188 dated May 24, 1983

Dear Mr. Collins:

The above referenced letter indicated submittal of a Final Report to the USNRC no later than August 26, 1983.

The completion of the corrective action is currently scheduled for December 1, 1983. A Final Report will therefore be submitted to the USNRC by January 6, 1984.

Very truly yours,

= - - - _ _ _

F. J. Drummond Manager, Engineering & Technical Services cc:

1)

Director 3)

Mr. E. L. Blake Office of Inspection & Enforcement U. S. Nuclear Regulatory Commission Washington, D.C.

20555 2)

Director 4)

Mr. W. M. Stevenson Office of Management Information and Program Control U. S. Nuclear Regulatory Commission Washington, D.C.

20555 8309080058 830829

_ _ 27 /fo PDR ADOCK 05000382

'""