Text

F o

g.

l Al1G 3 01983 Distribution L

3109.6/MJB/83/08/29/0 vWR file:

109.6 3001.4 WMHL r/f MJBell & r/f NMSS r/f HJMiller MEMORANDUM FOR:

Robert E. Browning, Acting Director J0 Bunting Division of Waste Management PDR FROM:

Michael J. Bell, Chief High-Level Waste Licensing Management Branch Division of Waste Management

~

SUBJECT:

MEETING 0F DATA RELEASE PANEL OF MATERIALS REVIEW BOARD, JUNE 13, 1983 l

L On the above date, I attended a one-day meeting of the Data Release Panel

[

'of the' Materials Review Board in Chicago, Illinois.

The purpose of the meeting was to review the first data package prepared by the Materials l

Characterization Center for inclusion in the DOE Materials Handbook.

The data package was for leaching of PNL.76-68 borosilicate glass for temperatures up to 90*C and for leach times up to one year.

A list of-attendees at the meeting is enclosed.

There was extensive discussion of the format for presentation of the data l

and numerous suggestions were made to improve the clarity of the presentation of the information.

An important point was that the tests were run while the MCC-1 static leach test-was still evolving,'so that i

the data were not obtained under the test procedure as it now exists.

A i

further. important point is that' the MCC-1 test itself is recognized to have several limitations and there are unresolved questions about the applicability of the data to repository conditions.

The position I took l-with regard to the data was that NRC would not object.to any reasonable format for presentation so long as the uses and limitations of the test.

1 l

method and any deviations from the test procedure were clearly identified

[

so that the user or reviewer could see whether the data were being i

properly applied.

I

[

It'was agreed that the MCC should revise the data package to take into account the comments of the Panel and that it would be submitted to the i.

.. M Record $61 MRB foy,jggjg at its next meeting.

W 1

I lO % 6 Docket No.

l

/

LPCil Michael J. Bell, Chief

c. Distribution; High-Level Waste Licensing Management Branch Division of Waste Management (Return to WM, G23 SS) g2.

Enclosure:

List of Attendeer

".p:_---_______-.___________-:__________--:__--_____

0FC

_ _ _ _ _. _ _' W_MH L NAME :MJBell: led :

8309070119 0'20830 DATE : 8/'30/83 PDR WASTE wpg_.1 PDR

I

, Enclosure 1 Attendees at Meeting of the Data Release Panel Materials Review Board Ramada-O' Hare Inn, Des Plaines, Illinois June 13, 1983 Present:

Panel Members:

Visitors:

l-M. Bell, NRC L. Daniel, MCC l

J. Berreth, Exxon M. Bowen, MCC R. Clayton, U of Chicago J. Haugen, DOE-Cll/MIO S. Coburn, U. S. Steel, ret.

C. Mcpheeters, ANL/MIO L. Dole, ORNL (alternate for W. Lackey)

H. Frederikse, NBS (alternate for T. Negas)

W. Gerberick, U of Minn.

D. Isherwood, NNWSI G. Maczura, Alcoa J. Mendel, MCC D. Moak, ONWI M. Steindler, ANL, Chairman l

Executive Secretary:

l l

W. Seefeldt, ANL l

Panel Member Not Present:

J. Burke, Consultant l

T y

y,

.m._

y

-