From: Gucwa L
GEORGIA POWER CO.
To: Stolz J
Office of Nuclear Reactor Regulation
References
NED-83-414, NUDOCS 8308050352
Download: ML20024D614 (1)


Text

.. -

Georgia Power Corrpany 333 Piedmont Avent.e Atlanta, Georgia 30308 Telephone 404 526 6526 Ma:i;ng Address:

Post Office Bos 4545 At!anta. Georg a 50302 Georgia Power L T. Gucwa

(? v sout%m e'ectic system Chief ?Juclear Eng neer Power Generabon Department NED-83-414 August 2, 1983 Director of Nuclear Reactor Regulation 4

Attention: Mr. John F. Stolz, Chief Operating Reactors Branch No. 4 Division of Licensing U. S. Nuclear Regulatory Commission

~ Washington, D. C.

20555 NRC DOCKET 50-366 OPERATING LICENSE NPF-5 EDWIN I. HATCH NUCLEAR PLANT UNIT 2 4

WITFORAWAL OF REQUESTED TECHNICAL SPECIFICATION CHANGE FEEDWATER TEMPERATURE REDUCTION 4

Gentlemen:

In accordance with the provisions of 10 CFR 50.90, on November 11, 1982 Georgia Power Company (GPC) proposed Technical Specification changes which would permit operation of the unit in the event of a partial loss of feedwater heating.

The reduced feedwater temperature calculations performed were cycle-specific and only applied to Hatch-2 Cycle-3 operation.

l GPC respectfully withdraws its request of November 11, 1982 regarding operation of Hatch-2 with reduced feedwater temperature for the following reasons:

This Technical Specification has not yet been approved by the Nuclear Regulatory Commission.

GPC did not operate Hatch-2 Cycle-3 with reduced feedwater temperature.

GPC has begun Hatch-2 Cycle-4 operation and the previous cycle-specific analyses for reduced feedwater temperature do not apply.

If you have any questions or comments regarding this matter, please contact our office.

Very truly yours, cYE f W L. T. Gucwa p /mb ULT xc:

J. T. Beckham, Jr.

yl H. C. Nix, Jr.

J. P. O'Reilly (PRC-Region II)

//O Senior Resident Inspector

/

8209050352 830802 PDR ADOCK 05000366 P