Text

, -

,' hi tYo s*

'l!I{C PDR.

AE0D CF AE0D RF C. Hsu, ROAB M 2 41983 E. J. Brown, ROAB K. Seyfrit, C/R0AB 49-3g C. J. Heltemes, AE0D M.-' M-D. C. DiIanni, IRR D. G. Eisenhut, NRR G. Lainas, NRR MEMORANDUM FOR:

liarold R. Denton, Director R. Clark, NRR Office of Nuclear Reactor Regulation FP.0fi:

C. J. lleltemes, Jr., Director AE0D/E313 Office for Analysis and Evaluation of Operational Data

SUBJECT:

POTENTIAL CONTAMINATION OF THE SPENT FUEL POOL AND PRIMARY REACTOR SYSTEM A recently completed Engineering Evaluation Report on the above subject is enclosed. Our evaluation concluded that two separate events at the same plant site, which involved cracking of fuel assembly nozzles in the spent fuel pool and in piping from the boric acid storage tank to the safety injection system, are indicative of degradation that resulted from contami-nation of the systems. Since the postulated sources of contamination were a contaminated batch of boric acid or resin intrusion due to the recycling system, the issue is potentially gen ric to PWR's.

Some important aspects are that:

(1) this type of contamination was not anticipated, (2) the water chemistry monitoring programs for the spent fuel pool and the pirmary niactor system do not analyze for sulfates, and (3) an unsuspecting licensee could inadvertently place a plant in a condition that may result in significant degradation of safety related equipment. We believe it would be prudent for NRR to consider establishment of requirements to include monitoring for sulfur contaminants in the water chemistry programs for the primary reactor system and the spent fuel pool.

anginal signed W C.J. Heltemes, Jr, C. J. Heltemes, Jr., Director Office for Analysis and Evaluation of Operational Data l

cc:

R. C. DeYoung, IE T. E. Murley, Region I J. P. O'Reilly, Region II g

J. G. Keppler, Region III

, h, J. T. Collins, Region IV g

i J. B. Hartin, Region V

}.f E. L. Jordan, IE B308030479 830624 PDR ADOCK 05000282 e

S PDR i

omce >!.......RQAB.M..

.......R0 AD d. 'AE0 SURNAMEh

............g

.f 6/p,ff/83 6M q/83 6/ p /83

,y,,

I me ronu ais om mcu oao OFFICIAL RECORD COPY imaroinn-en we