GO2-83-640, Forwards Interim Deficiency Repts on Reportable Conditions 49 & 248 & Final Deficiency Repts on Reportable Conditions 64 & 219.Next Rept Will Be Submitted by 831019

From kanterella
(Redirected from ML20024D217)
Jump to navigation Jump to search
Forwards Interim Deficiency Repts on Reportable Conditions 49 & 248 & Final Deficiency Repts on Reportable Conditions 64 & 219.Next Rept Will Be Submitted by 831019
ML20024D217
Person / Time
Site: Columbia 
Issue date: 07/20/1983
From: Carlisle C
WASHINGTON PUBLIC POWER SUPPLY SYSTEM
To: Martin J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
Shared Package
ML20024D218 List:
References
GO2-83-640, NUDOCS 8308030315
Download: ML20024D217 (1)


Text

F o

Q]to Washington Public Power Supply System P.O. Box 968 3000 GeorgeWashingtonWay Richland, Washington /993g (509)372-5000 Docket No. 50-397

~

' 4 l@ ey July 20, 1983 gggI'D,;:,

G02-83-640 Mr. J. B. Martin Regional Administrator U.S. Nuclear Regulatory Commission Region V 1450 Maria Lane, Suite 210 Walnut Creek, California 94596

Subject:

NUCLEAR PROJECT NO. 2 10CFR50.55(e) REPORTABLE CONDITIONS:

  1. 49, OPERATION OF STANDBY GAS TREATMENT SYSTEMS DAMPER; #64, PLANT ELLCTRICAL SEPARATION (PGCC); #219, IE CIRCULAR 81-05, SWAY STRUT /

SNUBBER END BUSHINGS; AND #248, ANACONDA FLEXIBLE CONDUIT

References:

1) Letter G02-82-803, dated August 17, 1982, R.G. Matlock to R.H. Engelken.
2) Telecon dated December 2, 1982, L.C. Floyd to J. Elin
3) Telacon QA2-83-062, dated March 21, 1983, L.C. Floyd to J. Elin.

In accordance with the provisions of 10CFR50.55(e), your office was notified of the above subject conditions as stated in References 1, 2, and 3.

Attachments I and IV provide interim reports on Conditions 49 and 248. Attachment II and III provide the Project's final reports on Conditions 64 and 219. We will continue to provide your office with quarterly updates on Condition 49 and 248 until resolved. The next report will be submitted on or before October 19, 1983.

If you have any questions regarding these subjects, please contact Roger Johnson, WNP-2 Project QA Manager, at (509) 377-2501, extension 2712.

Program Director, WNP-2 LCF/kd Attachments:

(4) As stated g8g g5]"

cc:

W.S. Chin, BPA N.D. Lewis, EFSEC A. Toth, NRC Resident Ins ector 3

Document Control Desk, NR h j[5h

.