ML20024C963

From kanterella
Jump to navigation Jump to search
Ro:On 830701,during Withdrawal of Adjustable Transient Rod Cylinder,Control Rod Began to Withdraw.Probably Caused by Dirt in Air Sys Due to Clogged Permanent Filter.Regular Maint of Filter Planned
ML20024C963
Person / Time
Site: University of California - Irvine
Issue date: 07/08/1983
From: Rogers P
CALIFORNIA, UNIV. OF, IRVINE, CA
To:
Office of Nuclear Reactor Regulation
References
NUDOCS 8307210237
Download: ML20024C963 (2)


Text

.

4

.s 4

~~ "UNIVE16sITY OF CALIFORNIA, ~IRVINE '

BERKELEY

  • IM/15. IRVINE
  • RIVERSIDE
  • MN IMIGO. MN FRANCIMD 5ANTA BARBARA. SANTA CRUZ

' DEPARTMENT OF CIIEMISTRY IRVINE, CALIFORNI A 92717

- July 8,1983 '

U.S. Nuclear Regulatory Commission Chief, Standardization and Special Projects Branch, Division of Licensing, Washington D.C.

20555 Re: Docket 50-326, License R-116 Incident Report for July 1,1983 Reported under Tech. Specs: 6.7.c.3. (abnormal occurrence)

Gentlemen:

An abnormal event occurred July 1,1983 at the UCI Nuclear Reactor Facility.

During a series of step insertions to generate maximum power and temperature curves, the adjustable transient rod cylinder was withdrawn to a height corre-sponding to a $2.00 insertion. At the upper limit of the cylinder's travel, the control rod began to withdraw. The reactor was critical at 1.5 watts and power increased to approximately 1.6 watts with a 20 second period.-

The reactor was immediately shut down. This incident was reported the same day to D. Sternberg of the NRC Region V Office.

Inspection of the cylinder's interior did not indicate a problem. Light oil was applied to the inside walls.This seemed to alleviate but not entirely eliminate the sticking of the piston during cylinder travel.

Another transient rod has experienced similar problems this past month.

L Both transient rods are serviced by the same' air system, so suspecting the problem may be due to contamination, this system was dismantled.

Fine dirt had accumulated in the air trap since it was serviced during monthly maintenance. Some dirt had passed through the trap and filter L

and entered the buffer tanks which supply air to the rods at 80 psi. These Q

L k

s 8307210237 830700 PDR ADOCK 05000326 S

PDR _,_

f tz

.i-c_

u_

tanks, valves, traps and air hoses were removed and cleaned. The permanent filter in the air trap was cleaned of accumulated debris. Each transient rod was opened, cleaned thoroughly with solvent and lubricated.

Specifications by General Atomics, manufacturer for the TitIGA Itcactor, call for clean, dry air to be used in the transient rod operation. While the air trap is cleaned monthly, the permanent filter attsfied to the system is not scheduled for regular maintenance. It is felt that it became overloaded and was no longer able to strain debris from the system, llegular maintenance of this item will most likely be added to our schedule.

When the system was reassembled each cylinder was tested thoroughly and no problems have since occarred. All rod drop times were in the normal range consistent with values obtained during tests over the last 2 years.

Itepairs to the rods and air system have been inspected and approved by the Acting llcactor Supervisor.

The I?acility will continue to operate on a conservative basis in the steady state mode only until Dr. George Miller, Itcactor Supervisor, returns in August. All pulsing operations will be delayed until repairs to the rod systems and air delivery systems have been inspected again and approved by the Itcactor Supervisor. Inspection of the air system will be made frequently during this time to avoid any further problems.

.Sincer ely,

/

L patricia J. It gers, Acting Itcactor Supervisor ec: NitC llegion V W.Lillyman, The Vlec Chancellor V.p. Guinn, Chair,110C Member,1100 G.E. Miller, Itcactor Supervisor i

-