7/- 9///

CHEM-NUCLEAR SYSTEMS INC.

k 240 stoneridge Drive, suite 100

  • 803/256-0450 g (ff/

June 29, 1983 RA-0149-3 W

}{r. Charles E. MacDonald Chief, Transportation Certification Branch Division of Fuel Cycle and Material Safety U. S. Nuclear Regulatory Commission E.

4 Washington, D.C.

20555

REFERENCE:

Docket Number 71-9111 NRC Letter Dated May 25, 1983

Dear fir. MacDonald:

Enclosed is our response to your questions of May 25, 1983 with regard to the amendment request for our Model No. CNS 6-80-2 package.

If I can be of assistance in answering any further questions, please feel free to contact me.

Sincerely, CHEM-NUCLEAR SYSTEMS, INC.

L. K. Poppe Corporate Health Physicist LKP:jg Enclosure s

(co o

DOCKg iy Q

ene f

N13 01993, ~@

ws2 s awm o

.s, 8307190266 830629 PDR ADOCK 07109111 C

PDR

V, RESPONSE TO NRC QUESTIONS DATED 5/25/83, DOCKET 71-9111 QUESTION:

Describe the method used to retain the 0-ring seals in the lid when the manufacturing option given in Drawing Note 3 is used.

ANSWER:

The 0-ring seals will be bonded with a light coating of RTV adhesive.

QUESTION:

Discuss the acceptance test and maintenance program to be used on the packaging when the optional lid seal configuration is used.

ANSWER:

A leak test shall be performed on the cask prior to acceptance.

The design internal pressure of the cask is 9.23 psi (see Section 2.4.4 of SAR).

Test pressure shall be 1.5 times the design or 13.8 psi.

The leak test will be accomplished using soap bubbles and a 14 psi test pressure.

No leakage will be allowed.

Test sensitivity is per ANSI 14.5.

7Property "ANSI code" (as page type) with input value "ANSI 14.5.</br></br>7" contains invalid characters or is incomplete and therefore can cause unexpected results during a query or annotation process. The maintenance program for tne optional lid seal configuration shall be as follows:

Prior to each shipment, the 0-rings shall be inspected.

The 0-rings shall be replaced with new 0-rings if the inspection shows a

defect which could prevent the package from forming a

seal, or every six
months, whichever occurs first.

Replacement and documentation shall be accomplished per CNSI Cask Handling Procedure, TR-OP-010.