3 Discharge Line Temperatures for December 1 - January 15 Identified RCS

'78 PORV ('F)

Code A('F)

Code B('F)

Leak Rate (qpm)

December 1 176 169 179

.3178 2

3 180 137 146

.1912 4

162 107 108

.2319 5

187 111 113

.1699 6

184.6 110.4 110.8 1.7710 7

183.1 110.5 111 8

184.5 111.8 112.1

.1394 9

182.8 113.5 113.8

.1729 10 185.1 115 115.4

.1587 11 185.3 115.4 115.7

.1556 12 183.9 114.2 115.5

.1862 13 14 184.4 113 114.2

.2075 15 183 119.1 120.1

.1923 16 183.1 111 112

.2004 17 181.4 110.3 111.9

.1872 18 176.2 104.6 105.7 19 176.4 99.4 100.5 20 182.2 107.2 107.9

.1709 21 182.4 109.8 111

.3516 22 182.3 109.1 110.4

.1953 23 182 111 111

.1851 24 181 112 112

.2055 25 185 115 115

.1841 26 184 114 115

.2513 27 184 114 115

.2024 28 184 115 115 29 160 190 180 30 177 111 119

.5701 31 185 115 115

.1672 S

e S

0

4%

Identified RCS

'79 PORV(*F)

Code A(*F)

Code B (*F)

Leak Rate (gem) ranuary 1

185.1 115.9 116.1 2

185.8 117.8 118.1

.5235 3

187.5 118.4 117.9 4

186.7 118.7 118.3

.3510 5

184 113 112

.6348 6

183 111 111

.4710 7

183.9 110.4 111.4

.4242 8

182.5 108.4 109.1

.3448 9

180.1 105.9 107.1 13 184.7 109.2 110.1

.5330 11 182.7 105.9 106.9

.7505 12 183.2 105.1 107.1 13 182.9 105.4 106.1

.5778 14 182.9 105.7 106.4

=15 180.2 103.5 105.1

.7121 Outage - January 15 through January 30.

2

__