i jut. 0 71983 MEMORANDUM FOR:
W. R. Mills, Chief. Events Analysis Branch, Division of Engineering and Quality Assurance,.IE FROM:
U. Potapovs, Chief, Vendor Program Branch, Division of Vendor and Technical Programs, Region IV
SUBJECT:
AITS NO. H07003271 - PART 21, BROWN & ROOT - ASCERTAIN IF THE THREE BROWN & ROOT PROBLEMS ARE PROPERLY RESOLVED (VITS81-153)
During the 99900521/83-01 inspection at Bechtel Power Corporation, Houston, Texas, office, actions and responsibilities relative to the subject item were evaluated.
-The purpose of this inspection was to determine the present status of these
, problems.
The three problems had been reported as 10 CFR.Part 21 deficiencies by Brown &
Root and are now being processed by Bechtel Power Corporation.
The results of the Region IV inspection are presented in'Section E.6 of the attached report.
^
- 8 We consider this item closed.
Please con a'ct tis lif you have a y questions.
s y
sny::A Q*70d UY'E U. POMrWf
,i Uldis-Potapovs,' Chief Vendo6ProgramBranch 4
cc:
R. L. Baer, IE R. F. Heishman, IE J. T. Collins, RIV R. L. Bangart, RIV SC:RSS
~BC:VP D:DV&TP
_JRCo ello/ mas.~
' 4 ff /83 hg/63
/ /83 CJHale UPotapovs-RLBangart 6 /l+/83 7120536 830707 GA999 EECBECH
<( p99900521 PDR