ARKANSAS POWER & LIGHT COMPANY POST OFFICE BOX 551 LITTLE ROCK, ARKANSAS 72003 (501) 371-4000 April 26, 1983 I%.tk @ [M M k l,
]
OCAN648320 I'
APR 2 81983 Mr. John T. Collins Regional Administrator h
U. S. Nuclear Regulatory Commission Region IV 611 Ryan Plaza Drive, Suite 1000 Arlington, TX 76011
SUBJECT:
Arkansas Nuclear One - Units 1 & 2 Docket Nos. 50-313 and 50-368 License Nos. DPR-51 and NPF-6 NPDES Noncompliance Report Gentlemen:
Attached are two copies of the NPDES Noncompliance Report.
This report is being submitted in accordance with NPDES Permit Number AR0001392, Part II, Paragraph A.2.
Very truly yours, EhnR. Marshall Manager, Licensing JRM:SAB:s1 Attachments cc:
Director of Nuclear Reactor Regulation ATTN:
Mr. J. F. Stolz, Chief Operating Reactors Branch #4 Division of Licensing U. S. Nuclear Regulatory Commission Washington, DC 20555 Director of Nuclear Reactor Regulation ATTN: Mr. Robert A. Clark, Chief Operating Reactors Branch #3
/
Division of Licensing I{?
U. S. Nuclear Regulatory Commission f
Washington, DC 20555 B305200490 830426 PDR ADOCK 05000313 S
PDR MEMBER MIDDLE SOUTH UTIUTIES SYSTEM
s, ARKANSAS POWER & LIGHT COMPANY FIRST NATIONAL BUILDING /P.O. BOX 551/UTTLE ROCK ARKANSAS 72203/l501) 371-7901 April 20, 1983 JOHN M. GRIFFIN Vice President 7 g m q r7 p>
g U., N Nuclear Operatens
}
t k { =>
An
'M w3 ARKAtG b iv,.
UGHT %
u E:mgy Sup;;y-Iw OpuaM CL-83-195 Mr. Dick Whittington Regional Administrator United States Environmental Protection Agency Region VI First International Building 1201 Elm Street Dallas, Texas 75270
REFERENCE:
Arkansas Nuclear One NPDES Permit Number AR0001392
Dear Mr. Whittington:
This letter represents a noncompliance report as required by Part II, Paragraph A.2 of the above-referenced Permit.
On April 13, 1983, routine analysis of a sample from outfall 003, the oily water separator, revealed an average oil and grease concentration of 25 mg/l and a pollutant load of 27.9 lbs per day. The permit limits for oil and grease (pa-rameter) are 15 mg/1, 25 lbs/ day, and 20 mg/1, 33 lbs/ day, daily average and daily maximum, respectively. All other parameters were within permit limits.
Investigation of this violation has revealed the cause to be related to a bear-ing failure on the Unit One turbine at this station. Oil escaped from this bearing into the turbine building sump where it drained into the oily water separator. Upon detection of this exceedence, the wastewater was rerouted to the emergency wastewater holding pond. At the same time, the unit was shut down for repair of the turbine bearing. Later, monitoring revealed that this outfall was back within permit limits by 9:00 p.m. on April 13, 1983.
It should be noted that considerable effort was expended to prevent the bearing lubrication oil from entering the floor drains by erecting barriers to retain the oil. The relative success of the effort can be measured by considering the total available amount of oil that could have entered the drains and the con-centration detected at the outfall. When the bearing failed, approximately 200 gallons of oil were released; as previously indicated, only 25 mg/l was detected at the outfall. Retained oil was collected and disposed by way of our waste oil tank.
uc m en..nn...n.,m.,v
.r...
var...
=%
. 1*
g e
CL-83-195 l
Mr. Dick Whittington April 20, 1983 Page Two As preventative and corrective measures, we are cleaning the turbine building sump, and are in the process of repairing the turbine bearing. These actions should mitigate against a recurrence of this type violation.
Very truly years, eM ghqLJohnGriffin JG/DLS/twr cc: Messrs. J. L. Maulden C. L. Steel t
J. D. Phillips M. L. Pendergrass D. L. Swindle W. G. Coleman I
J. M. Levine T. C. Baker J. R. Marshall (NRC)
Dr. Phyllis Garnett (ADPC&E)