Amend 85 to License DPR-50,permitting Controlling Explosive Gas Mixtures in Waste Holdup Sys by Limiting Hydrogen to 2% by Vol W/O Limit on Oxygen Concentration
ML20023C848
Person / Time
Site: Crane 
Issue date: 05/05/1983
From: Stolz J
Office of Nuclear Reactor Regulation
To:
Metropolitan Edison Co, Jersey Central Power & Light Co, Pennsylvania Electric Co, GPU Nuclear Corp
Shared Package
ML20023C849 List:
References
DPR-50-A-085 NUDOCS 8305180104
Download: ML20023C848 (4)


Text

,

f* ** Coq'o,

{

UNITED STATES

'i NUCLEAR REGULATORY COMMISSION

[

~

c.,

WASHINGTON. D. C. 20555

.j N..v,/

METROPOLITAN EDISON COMPANY JERSEY CENTRAL POWER'AND LIGHT COMPANY

. PENNSYLVANIA ELECTRIC COMPANY,

GPU NUCLEAR CORPORATION DOCKET NO. 50-289 THREE MILE ISLAND NUCLEAR STATION, UNIT NO. 1 AMENDMENT TO FACILITY OPERATING LICENSE-Amendment No. 85 License No. DPR-50 1.

The Nuclear Regulatory Comission (the Comission) has found that:

A.

The application for amendment by GPU Nuclear Corporation, et al (the licensees), dated February 3,1983, as revised April 14, 1983, complies with the standards and requirements of the Atomic-Energy Act of 1954, as amended (the Act),.and the Comission's rules and regulations set forth in Chapter-I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of 4

the Comission; C.

There is reasonable assurance (i) that-the activities authorized by this amendment can be conducted without endangering the health l-and safety of the public, and (ii) that such activities will be L

conducted in compliance with the Comission's regulations; l

D.

The issuance of this amendment will not be inimical to the comon l

. defense and security or to the health and safety of the public; p

and

~

E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.

i A

O 000 P

PM l

.1

.~.

2.

Accordingly.,the license is amended by changes to the Technical Specifications as indicated in the' attachment to this license amendment,-and paragraph 2.c.(2) of Fa'ility Operating License c

No. DPR-50 is hereby amended to read as follows:

t (2) Technical Specifications The Technical Specifications contained in Appendix A, as revised through Amendment No. 85, are hereby incorporated in the license. GPU Nuclear Cor-poration s. hall operate:the facility in accordance with the Technical Specifications.

3.

This license amendment becomes effective upon initial operability of a redundent hydrogen monitor.

FOR THE NUCLEAR REGULATORY COMMISSION

~-

L oin F. Stolz, Chief h Op)eratingReactorsBranch#4

('-Division of Licensing

Attachment:

Changes to the Technical.

Specifications i

Date of Issuance: May 5,1983 s

l l

l l

l l

l 1

I

.c

ATTACHMENT TO LICENSE AMENDMENT NO. 85 FACILITY OPERATING LICENSE NO. DPR-50 DOCKET NO. 50-289 Replace the following page of the Appendix ~"A" Technical Specifications with the enclosed page. The revised page is identified by Amendment number and contains vertical lines indicating the area of change.

Remove.

Insert 3-116 3-116 t

4 f

l e

9 l

Q RADICAC IVE EFFLt.I'CS EXPLOSIVE GAS MITTiJRZ LIMIT!NG CONDITIONS FOR OPERATION 3.22.2.5

  • The concentration in the waste gas holdup system shall be limited l

to less than or equal to 2*. oxygen by volu=e and 4% hydrogen by volume 9xcept that until Cycle 5 criticality, the concentration-in the waste gas holdup system shall be limited to less than or

' equal to 2% hydrogen by volume with no limit on oxygen concentration

(_see

  • footnote).

1 APPLICABILITY:

At all times.

ACTION:

  • With the concentration in the vaste gas holdup system greater l

a.

than 2* oxygen by volume or 4% hydrogen by volume, immediately minimize additioris of vaste gases to the system and reduce the concentrations to less than the aforementioned values within one hour.

  • Prior to Cycle 5 criticality:

With two hydrogen monitors OPERABLE and the concentr'ation in the waste 1.

gas holdup system greater than 2% hydrogen by volume, i mediately mini-mize additions of waste gases to the system and reduce the concentration to less than or equal to 2% hydrogen by volume within.one hour.

With one hydrogen monitor OPERASLE commence taking a grab sa=ple every 2.

8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> and if the concentration in the waste gas holdup system is greater than 2% hydrogen by volume,1:=nediately minimize additiens of waste gases to the system and reduce the concentration to less than or equal to 2%

j hydrogen by volume within one hour.

With no, hydrogen monitors OPEPM LE, the concentrations in the waste gas I

3.

holdup system shall be ' limited;to less than or equal to 2*; oxvgen by volu=e and 4% hydrogen by volu=e.

i 3-116 Amendment No. 72, 85

. _ _ _ _