i D

MAY 2 3 33 Mr. E. P. Rahe, Jr., flanager Westinghouse Electric Corporation Box 355 Pittsburgh, Pennsylvania 15230

Dear Mr. Rahe:

Subject:

Request Number 1 for Additional Information on WCAP-8720, Addendum 3 We are currently reviewing the Westinghouse Electric Corporation Licensing Topical Report WCAP-8720, Addendum 3 entitled " Improved Analytical !!odels Used in Westinghouse Fuel Rod Design Computations /

Application for BWR Fuel Analysis."

The initial review reveals the need for the additional information indicated in the enclosure.

In order to complete this review within the current scheduled time, responses to all questions should be received by NRC by June 25, 1983. Please advise D. H. floran at (301) 492-9777 if this date is unacceptable.

l Sincerely, r

i Cecil 0. Thomas, Chief l

Standardization & Special l

Project.s Branch Division of Licensing

Enclosure:

l As stated l

NHE DISTRIBUTI0ft:

@[

. Antral Files

@g NRC PDR Ug PRC s

NSIC l

$gg C. Thomas

'" p l

o n.

P. Anderson oO C. Berlinger G

f l

D. Moran Fd I

8E Jr Voglewede w/o. enc 1.

@ure lgc /4 gq.

nnR La.o b#

o r

nv

'DL! SSP.

l L:

PB D Q CP 7 "U5br ~ :Ec der omas CBerlinger

........g...'..-

..g;.g.' son suR-E >

3..

.;. 3....

.g.g..

DATE )

......... ~

NRC FORM 318 00-80) NRCM ONO OFFIClAL RECORD COPY esom --muo

REQUEST FOR ADDITIONAL INFORMATION ON WCAP-8720, ADDENDUM 3

~

1.

In response to staff questions on Addendum 1 to WCAP-8720, it was shown (Ref.1) that the power histories used by Westinghouse to evaluate LOCA initial conditions give essentially the same values of peak fuel temper-ature as are obtained by continuous operation at the maximum pennitted power level (as required by Section I.A of 10 CFR 50 Appendix K).

Please demonstrate that this continues to be the case for the low fill gas pressure BWR design, where peak fuel tenperatures may no longer occur near beginning of life.

2.

Addendum 3 to UCAP-8720 states that the Westinghouse BWR fuel will have the sane thermal, physical and mechanical properties as the current PWR fuel.

During a February 24,. 1983 meeting with the staff, however, Westinghouse stated that gadolinia will be incorporated in the BWR design.

Other BWR fuel suppliers have shown (Refs. 2-3) that the addition of gadolinia to urania alters both the material properties and the irradiation character-istics of the fuel.

Please describe how the PAD computer code will account for these effects and whether the manner in which the code is applied (e.g., Response 6 of Reference 1) will change with the addition of this burnable poison.

If the irradiation characteristics of the fuel are not expected to change with the addition of gadolinia, please supply the irradiation data on which this assumption is based.

I

REFERENCES 1.

T. M. Anderson (W) letter NS-TMA-2303 to J. R. Miller (NRC) on " Responses to Request for Additional Infomation on Addendum 1-to WCAP-8720," dated September 9,1980.

2.

G. A. Potts, "Urania-Gadolinia Nuclear Fuel Physical and Irradiation Characteristics and Material. Properties," General Electric Company Report NED0-20943 (non-proprietary), January 1977.

3.

L. D. Gerrald and G. C. Cooke, "Gadolinia Fuel Properties for LWR Fuel Safety Evaluation," Exxon Nuclear Company Report XN-NF-79-56 (non-proprietary, revised, and supplemented), December 10, 1982.

__