SAFETY EVALUATION REPORT Docket No. 71-9341 Model No. BEA Research Reactor Package Certificate of Compliance No. 9341 Revision No. 9
SUMMARY
By application dated December 2, 2019 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML19336D898), Orano Federal Services, LLC (OFS or the applicant), requested that the U.S. Nuclear Regulatory Commission (NRC) renew the Certificate of Compliance (CoC) No. 9341 for the Model No. BEA Research Reactor (BRR) package. OFS did not request any changes to the package design or its authorized contents. The certificate has been renewed for a five-year term.
EVALUATION The staff reviewed the documents referenced in the certificate and determined that the documentation was available and complete.
CONDITIONS Condition No. 10 has been updated to reflect the new expiration date.
The references section of the certificate was revised to include the date of the certificate renewal request and to delete unnecessary references.
CONCLUSION The certificate has been renewed for a five-year term, which expires on February 28, 2025.
Based on the statements contained in the application, and the conditions listed above, the staff concludes that the changes indicated do not affect the ability of the package to meet the requirements of 10 CFR Part 71.
Issued with Certificate of Compliance No. 9341, Revision No. 9.