From:
Vechioli Feliciano, Lucieann To:
Theo Odendaal (theoo@x-energy.com); Waites, Brandon Wiley; Clint Medlock Cc:
Diaz-Castillo, Yamir
Subject:
DRAFT RAIs NRC Assessment of the Xe-100 Nuclear Reactor Quality Assurance Program Description version 2 Date:
Monday, December 16, 2019 3:50:00 PM Attachments:
Draft Request for Additional Information X-Energy QAPD (After Phone Call Nov 26 2019).docx Theo et al.
Please see attached revised RAIs for the Xe-100 reactor QAPD. The revised version takes into consideration our clarification call held on Nov 26, 2019.
Please note that it is important for us to comprehend what will be X-Energys role in the areas that although are not applicable for a DC, you still plan to perform.
The NRC staff is available for a discussion call the following dates:
Tuesday (tomorrow) Dec 17 10am Wednesday Jan 8th 10am or 1pm Thursday Jan 9th 9am or 3pm
Thanks and Happy Holidays!
Lucieann Vechioli Feliciano Project Manager U.S. Nuclear Regulatory Commission NRR/DANU/UARL Phone: (301) 415-6035 Location: OWF 02-H22 Mail Stop: O-12D20 Email: Lucieann.Vechioli@nrc.gov
P Please consider the environment before printing this e-mail