ML20012G540

From kanterella
Jump to navigation Jump to search
Provides Utils Response to NRC Bulletin 90-001,Supplement 1, Loss of Fill-Oil in Transmitters Manufactured by Rosemount
ML20012G540
Person / Time
Site: Trojan File:Portland General Electric icon.png
Issue date: 03/04/1993
From: Robinson W
PORTLAND GENERAL ELECTRIC CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
IEB-90-001, IEB-90-1, NUDOCS 9303090031
Download: ML20012G540 (2)


Text

.

r A

m

_ ee!

e Portland General Electric Company a

C'"

James E. Cross Vice President and Chief Nuclear Officer March 4, 1993 l

Trojan Nuclear Plant Docket 50-344 License NPF-1 i

U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington DC 20555 i

Dear Sir:

Response to Bulletin 90-01, Supplement 1, " Loss pf F111.-011 in Transmi.tl.tttiLilanufactured by RqEempant" The purpose of this letter is to provide Portland General Electric Company's (PGE's) response to Nuclear Regulatory Commission (NRC)

Bulletin 90-01, Supplement 1.

The bulletin requests particular actions from operating reactor licensees regarding Rosemount transmitters, Model 1153 Series B and D and Model 1154 manufactured prior to July 11, 1989, used in safety-related systems or installed in accordance with Title 10 to the Code of Federal Regulations, Part 50.62 (10 CFR 50.62).

PGE does not have the Rosemount transmitters of concern installed in the l

Trojan Nuclear Plant (TNP). The TNP reactor has been shutdown and defueled permanently and PGE has submitted a request to the NRC for an amendment to the TNP Operating License to prohibit power operation.

Since the Rosemount transmitters of. concern are not installed at TNP, PGE will not be performing any enhanced transmitter monitoring.

Sincerely, W. R. Robinson for J. E. Cross f

c:

Mr. John B. Martin Regional Administrator, Region V U.S. Nuclear Regulatory Commission Mr. David Stewart-Smith State of Oregon Department of Energy 08018ya t

Mr. Kenneth Johnston NRC Senior Resident Inspector Trojan Nuclear Plant f

DO

/#

1 '

o 121 SW Salmon Street, Portland, OR 97204 503/464-8897 L

y s

4 l

i

)

STATE OF OREGON)

)

i COUNTY OF COLUMBIA)

)

1. W. R. Robinson, being duly sworn, subscribe to and say that I am the Vice President, Nuclear for Portland General Electric Company, the applicant herein; that I have full authority to execute this oath; that I have reviewed the foregoing; and that to the best of my knowledge, infermation, and belief the statements made in it are true.

l Date 3-

, 1993 f

d ae -a g d W. R. Robinson Vice President, N:,. clear l

On this day personally appeared before me W. R. Robinson, to me known to be the individual who executed the foregoing instrument, and acknowledged that he signed the same as his free act.

GIVEN under my hand and seal this M

day of hSCWb

, 1993.

au d i2. Soww Notary Public in and for the State of Oregon Residing at O MLd My commission expires Ul0Mh C 9.177f D

4

+

-n,.

-- -