ML20012C566

From kanterella
Jump to navigation Jump to search
Forwards Application for License to Export Low Enriched U for Use in Sweden.Ltr of Assurance Required
ML20012C566
Person / Time
Issue date: 03/16/1990
From: Peterson M
NRC OFFICE OF GOVERNMENTAL & PUBLIC AFFAIRS (GPA)
To: Hart T
ENERGY, DEPT. OF
References
NUDOCS 9003220212
Download: ML20012C566 (1)


Text

.

y w. e w.... u..u c..,.

h D

j&Re:vq{

UNITED STATES '

NUCLEAR REGULATORY COMMISSION

~,

r.

.n

.[

'i l

WASHINGTON, D. C. 20555

~'

l I

MAR 161990 Mr. Ted Hart

.U.S. Department of Energy Office of International Affairs Mail Stop IE-13 Washington,;D.C. 20585

Dear Mr; Hart:

Enclosedisanapplicationforanexportlicense(XSNM02509),recently received by the Nuclear Regulatory Connission, for the export of low-enriched uranium for conversion and fabrication-in Sweden. The material will then be returned to the U.S. for use as fuel in the Peach Bottom 2 and Limerick 2

. reactors. Assurances from Sweden are required that the material will be subject-to all.of the terms and conditions of an agreement for cooperation. Your assistance in obtaining the necessary assurances will be appreciated.

Please note that the material is of Canadian origin.

Sincerely, L-Marvi

.R. Peterson, Assistant Director for International Security, Exports and Materials Safety International Programs L

Office of Governmental and Public Affairs.

L

Enclosure:

E Appl. dtd 3/8/90 4

(XSNM02509-Sweden) cc.w/

Enclosure:

L J. Rooney, DOE h

R. DeLaBarre DOS N. Martin, DOE ~

M. Rosenthal, ACDA G. Brubaker, D0D G. Kuznlycz, DOC 9003220212 900316 PDR XPORT XSNM-2509 PDC D

i

' q *,FOR3 NIC-7

' U.S.NUCLEA3 CLEIULATORY COMMISSION APPHOVES SY C AO 1

lor $tio APPLICATION FOR LICENSE TO EXPORT NUCLEAR m 22stRo3s2) e, MATERIAL AND EQUIPMENT (see /mtructions on Rewese/

1. APPuCanT 5 je. DATE or AertiCATios b. ArrLiCANT S REFERENCE 2.NRC J a, sleensT i

s a wo.

USE

March 8, 1990 MIS-508 USE

- // h h

M

3. APPLICANT'S NAME AND ADDRESS l Rlt
4. SUPPLIER'S NAME AND ADDRESS A88 (Compkre if apptwent a not supptoer of materia!)

Transnuclear. Inc.

U.S.D.O.E.

4

n. ST RE ET ADDRESS e.NAME Two Skyline Drive Mar +4n Ma ri o t ta rnerev systems. Inc.

l

c. CITY STATE ZIP CODE
b. STRE ET ADDRESS Hawthorne NY 10532 3970 stato poute 21 south
c. T E LEPMoN E NUMSE R (Aree Coor - humber - Essensen)
c. CIT Y STATE ZIP CODE (914) 347-2345 Ext. 3056 Piketon OH 45661
6. FIRST SHIPMENT
6. FINAL SHIPMENT 7. APPLICANT'E CONTRACTUAL 8. PROPOSED LICENSE
9. U.S. DEPARTMENT OF ENERGY SCHEDULED SCHEDULED DELIVERY DATE EXPIRATION DATE CONTR ACT NO. fif Known1 Three years from S<utember 1990 N/A Same as item 5 date of issuanCo DE-SC05-84UE87532
10. ULTIMATE CONSIGNEE l RIS I 11. ULTIMATE END USE l

(inctuon plant or facitory name)

,uauy ABB Atom AB For Conversion and fabrication of fuel.

b. STRE E T ADDRESS paDriCated fuel elements will be returned m-791. 61 to the U.S.

to be used in the Peach-

c. cit Y - ST AT E - CoVNT R Y Bottom'2 as reload 8 and in the Limerick 2 Uneterne.

c't..a cl a n 11a EST.DATE OF FIRST USE am reinnd 1

12. INTERMEDI ATE CONSIGNEE l RIS

. 13. INTERMEDIATE END USE l

e.NAME Ledoux and Company Shipper of record for sampling procedures,

b. STREET ADDRESS Surveillance and analysis of weighing.

1%4 Alfrnd Avnnno

c. CITY - ST ATE - COUNTRY Tenneck. N.T usa 13a. EST. DATE OF FIRST USE
14. INTERMEDIATE CONSIGNEE l RIS

. 15. INTERMEDIATE END USE l

3 NAME

b. STREET ADDRESS
c. CITY - ST ATE - CDUNTRY 15e. EST. DATE OF vlRST USE 14.
17. DESCRIPTION
18. MAX. ELEMENT 19. MAX. 20. MAX 21.

NRC finclude chemicalano physical form of nuckar materiefeenve dotter vslue oI USE nurkar envrpment nW comoonents) wE1GHT WT. %

1 SOT 09E WT.

UNIT Uranium in the form of Uranium Hexafluoride, Uranium U-235 enriched to 4.25 w/o maximum 954.75 4.25 40.6 Kgs.

4

22. COUNTRY OF ORIGIN.-

l ~ F>t ' - l 23. COUNTRY OF ORIGINrSNM

[*

I 24. COUNTRIES WHICH ATTACH Ir*

l SOURCE MATE RI AL WHERE ENRICHED OR PRODUCED SAFEGUARDS (if Known/

Canada 1

25. ADDITIONAL INFORMATION (ver asperere sheet //nscassaryf
26. The opphesnt sortifess that this opphastion is propened pnformity wrtth Title 10. Code of Federal Regulatsons, and that all information in this appliestion is correct to the best of his/her knowledge./

h Np 9

b. TITLE
27. AUTHORIZED OFFICIAL
a. SIGNATURE ' f g g

,I ggg gg w

.1 wm

.us t

U

  1. b
wimanner m at XSdn702669
3. ;..

ra.nex un j/00ifg(&

v PHLASELPHfA.PA,191of '

Bielass. esse

. mu.iam w.sumi. m

. February 15. 1990 mannage.sweemasse Mr. Glenn Griffiths Chief. North American Branch tustness opere.tfons ptviston Department of Energy-

)

~

cak Ridge Oporttfons P.O. Oos I Cak Ridge. TN 37831 SUB3tCT:

Peach gottom 2, Reload 8 and Limerlek 2, Aeload 1

~

180-day Eartchment Nottffcation for A881.ead fest Assemblies

REFERENCE:

Letter to G. Grifff ths (800 from N. J. Alexander dtCo)

June 5. 1989

~

y

Dear Glenn:

lased on. the provistent of Article HI, Paragraph 4 of the DOC Utility Servlees (US) Contract No. DE-SC05-84-UW7532 and the reference letter agreement dated June I,1989, we hereby provide our 180-day provisional notificatice to accomodate the beginning or enriched predect delivery on September 1.1990 for peach Betten 2, Reload 8 and timeriii 2. Reload 1.

The attacturd table provides enriched prodvet delivery dates, quantities and assays of enriched urante regatred for the subject reload.

He request that' Dot provide the following:

  • Provide 1he "Special Assays Variation" for those assays notti on the attached table.
  • Transfer 9,014 KgU-at natural UF4 from PECo's' Usage Agreteent Account No..

DE-SC05-75-U405179 to DOE US Accovet No. DE-5C05-84-UIC7532 en or tiefer c

15, 1990 to meet the feed delivery'reestrement.

This preliminary uterial l

transfer quantity notification may be changed by our final notification.

1 N

Kindly acknowledge recelet of this notification and associated attached table by signing and returning one copy of this letter.

i.

l Very truly yours, k) kbe.Q

\\

By:

W J. Alexander i

ethntes1 Beyer

Title:

l Date:

attachment W. !!. 5.with, III - (.. F. Rubinc - R. J. Conti/R. M. Casper - SFNFlie cc:

MA 8t 6 'So 14 23 PE FUEL PRCOUREMENT FAGE 880 k

r e e,_ m e. m ~

~

~

,su pe:

I s

~

L w

{

.(

~

HIRNEERIIA ElfN O(3550l[

.*Q Beads awet-2,. Eadames a N_ h is* 2,-321084 1 pallweer pate, emed*ile= asut mamara 6

N 180-Osy T h*-# Neitificattera

)

OEh, No. 23-6005-88ERf7532 Imad ' Jest Ama*=Mlen (IER)

EdFttidn931E_g B30838CT:

HEGOED 10.

PROERK.T ASB4Y 454EEVIAR -

ASSAY BEAC10BVDEIORD Ifma DELEVERY IEEE W/O 19-235 (EGWU)

M AMED ASShY ESfDWtrIiB 1RIUB Peads ibLtan 2, Reload a 4

W h, 1990 4.20 475

-t i

31:nerick 2, Reload.1.

Ipecial 2687 0.30%'

i 4

Septentzer,1990 4.20 475 special 26AZ 0.3st

'romt, srie Product Eeoeiver/Itansporters ABD Atom RB) IEI2VERY N.EE:

i i

IEACICOyREEa4D ButHBab UF i

ERfAVWlY OfGR ORIDIN alpy gru m 6

Beach Bottan 2, neload 8 By 05/15/90 Canada 4507 DOE,(Umage Agreement Account Lbnerick 2, meload L No. M H9005 ~MIMD5179)

By 05/15/90 omada 4507 Dos pharp agr== ort hv==rt 30 0. IMC-600976UR05179)

'AtNE S014 t

,e t

e

.e p

  • g e

8

.~

m

t 3

1...

1 1s-U.,+

,c.

RECElVED h-TitANSNbCLEAR,INC.

USC h

p) mR12L A6:19 EXPORT IMPOD~

INT L SAFEGU/,Ru!

March 8, 1990 X5dmoS609 i

i t DouaW United States Nuclear Regulatory Commission One White Flint North Mail Stop 3-H-5 Washington, DC 20555

. Attn Mr. Marvin Peterson Re:

Export License Application for ABB-Atom TNY Ref: MIS-508.

Dear Mr..Peterson:

Enclosed is an export license application and its end use statement for your handling of the following:

40.6 Kgs Uranium-235, contained in 954.75 Egs Uranium, in the form of Uranium Hexafluoride, enriched to-4.251 maximum The above figures-include tolerences.

i Please call me-if you have any questions.

e Very truly yours,

'O

)

b... m %CL ruD h

'd. -%.

i 1

Patricia B. Quain-

-Traffic' Coordinator PBQ=

Enclosures i-I TWO SKYLINE DRIVE

  • HAWTHORNE, NEW YORK 10532 2120 TELEPHONE: 914-347 2345
  • FAX: 914 347 2346
  • TELEX: 6818082

,