ML20012C136

From kanterella
Jump to navigation Jump to search
Part 21 Rept Re Failure of Connecting Rod in Standby Diesel Generator 22.Initially Reported on 891208.On 891128,master Connecting Rod Failed.Caused by over-drilling of Oil Holes. Final Rept, Finite Element Analysis of KSV-4-2A... Encl
Date released: 01/26/2020 Download: ML20012C136


Final Rept AM-1852-C-1A, Finite Analysis of KSV-4-2A Master Connecting Rod, Applied Mechanics Rept
ML20012C169
Person / Time
Site: South Texas 
Issue date: 02/26/1990
From: Horne J
COOPER INDUSTRIES, INC.
To:
References
REF-PT21-90
Download: ML20012C169 (47)
Part 21 Rept Re Failure of Connecting Rod in Standby Diesel Generator 22.Initially Reported on 891208.On 891128,master Connecting Rod Failed.Caused by over-drilling of Oil Holes. Final Rept, Finite Element Analysis of KSV-4-2A... Encl
ML20012C135
Person / Time
Site: South Texas 
Issue date: 03/08/1990
From: Stolba F
COOPER INDUSTRIES, INC.
To: MURLEY T E
Office of Nuclear Reactor Regulation
References
REF-PT21-90, REF-PT21-90-040-000
Download: ML20012C135 (4)