ib
,,j;?
s?-'
f' as
' UNITED ST ATES 9.'
NUCLTAR CEGULATORY COMMi$$ TON t
REGION ll
- 'j 101 MARIETTA STREET.N.W.
ATLANTA. GEORGI A 30323 1 i Report No.: 70-1252/90-01 Licensee: Edlow International Docket No.: 70-1252 Facility Name: Portsmouth Marine Terminal Portsmouth, VA Inspection o. c'ted:. February 12. 1990 3 / 7 /90 Inspector..
I
. Ennis, Safeguards Inspector
~Da'te Signed Accompanying, Personnel: IW. C. Floyd, Division of Safeguards and Transportation -
Office of Nuclear Material Safety and Safeguards 3 h [8 Approved by v.
^:
D. R. McGuiN, Chief ITatV Signed i
Safeguards Section Nuclear Materials Safety and Safeguards Branch Division of Radiation Safety and Safeguards
SUMMARY
'- h Scope:
This routine unannounced inspection was conducted in the area of physical protection of shipments of irradiated reactor fuel.
7
~.
'Results:
^:
In the area inspected, violations or deviations were not identified.
p' i
4 5
.g
- ) -
i -;
I 9003130623 900307 o
PDR ADOCK 07001252 g
a c.
,t,',
e s
t REPDRT DETAILS p
r i-..
1.
Persons Contacted Licensee Employees e
"N. L. Ravenscroft, Vice President, Edlow International Company
- R. H. Fisk, Vice President - International, Edlow International Company Other Organizations E
S. Seki, Manager, Hitachi Transport System ( America), Ltd.
K. Inoue, President, International Engineering Co., Ltd.
R.-Mori, Deputy Manager, Business Dept., Nippon Nuclear Fuel Development Co., Ltd.
L.. Lewis, Sergeant, Virginia Port Authority Police r
J. Vester, Safety Director, Virginia International Terminals, Inc.
' Attended exit interview 2.
Physical Protection of Shipments of Irradiated Fuel (81310)
The inspector verified that: the shipper (Edlow International) had made the shipment notifications required by 10 CFR 73.37(f)(2) and that the notifications contained the information required by 10 CFR 73.37(f)(3),
arrangements had been with the Virginia Port Authority Police for support and assistance during the time that the shipment-was at the Portsmouth L
Marine Terminal in accordance with 10 CFR 73.37(e), and communications checks were made in accordance with. the provisions of 10 CFR 73.37(b) during the_ time that the shipment was in port.
The ' inspector surveyed the shipment with - a calibrated Eberline ESP-2 meter.
Beta gamma readings on contact with the outsidef of the USA /0388/B(M)F container were less that I mR/hr.
Smears taken from the i
package surfaceL read, af ter correcting for the detector's efficiency, less than 800 counts per minute (beta gamma).
F No violations of regulatory requirements were identified.
- 3. -
Exit Interview The inspection scope and results were summarized on February 12, 1990, with those persons indicated in paragraph 1.
The ' inspector described
.the areas inspected and discussed in detail the inspection results.
Proprietary information is not contained in this report.
Dissenting comments were not received from the licensee, o
m