N,,,.

)

February 9, 1990 j

i f

Docket'No. 50 336 1

MEMORANDUM FOR: -John F. Stolz, Director j

Project Directorate 1 4-Division of Reactor Projects - I/II

)

FROM:

Guy S. Vissing, Project Manager Project Directorate 1 4 Division of Reactor Projects - I/II

SUBJECT:

FORTHCOMING MEETING WITH NORTHEAST NUCLEAR ENERGY COMPANY CONCERNING STEAM GENERATOR TUBE' INSPECTION RESULTS AND OTHER STEAM GENERATORS ISSUE FOR MILLSTONE UNIT 2 DATE & TIME:

Thursday, February 22, 1990 10:00 a.m.

3:00 p.m.

i LOCATION:

One White Flint North

-i 11555 Rockville Pike j

s Rockville, Maryland Room 14B11-PURPOSE:

To discuss the results of recent steam generator tube inspection for Millstone Unit 2

  • PARTICIPANTS:

NRC-Northeast CY. Cheng Bill Hutchins, et al.

K. Whichman E. Murphy J. Strosnider G. Vissing L. Shao J. Stolz

~

F. tlitt J. Richardson

= $o P. Hebighorst

ogg s/
go.

o8 So Guy S. Vissing, Project Manager ex Project Directorate I-4

$8 Division of Reactor Project - I/II of cc: See next-page

'Mon-

,j@g

  • Meetings between NRC technical staff and applicants or licensees are open for l

interested members of the public, petitioners, intervenors, or other parties to attend as observers pursuant to "Open Meeting Statement o NRC Staff Policy,"

l 43 Federal-Register 28058,6/28/78.

. s\\ L.

a OFC :LA:PDI-4

PM:PDI :PD DI-4

'NAME :S s

(g:1m :JSt

............. N

'DATE:2/7/90:

2/7 /90
2/ /90 UttiblAL KLUUKU LUPT Document Name: MTG 2/22 d

r 01STRIBUT10N FOR MEETING.WOTICE DATED:

February 9,-1990

. WW NRC & Local PDRs-PDI-4 Reading:

T.Hurley/J.Sniez'ek(12G18)

. J.Partlow.(12G18)

. S.Varga(14E4)=

U B. Boger

. S. Norris G. Vissing-W.Lanning(11E22) l 000 E. Jordan (MNBB-3302)

Receptionist (One White Flint North)

. NRC Participants.K. Whichman E. Murphy J-Strosnider G. Vissing L. Shao J. Stolz F.-Witt-J.. Richardson.

P. Habighorst ACRS (10)

LGPA/PA L. Thomas (12E4)

-V. Wilson (12H5)

'J.! Dyer (RegionI,17G21)

K.. Abraham (Region I) 4 =

~

i

' ?*.' ;

},

' ^

Mr.4 Edward J. Mro d a Millstone Nuclear Power Station Northeast Nuclear nergy Company Unit No. 2 cc:

Gerald Garfield, Esquire R. M. Kacich, Manager Day, Berry and Howard Generation Facilities Licensing l

Counselors at Law Northeast Utilities Service Company City Place Post Office Box 270 Hartford, Connecticut 06103-3499 Hartford, Connecticut 06141-0270 W. D. Romberg, Vice President D. O. Nordquist Nuclear Operations Manager of Quality Assurance Northeast Utilities Service Company Northeast Nuclear Energy Company Post Office Box 270 Post Office Box 270 h

Hartford, Connecticut 06141-0270 Hartford, Connecticut 06141-0270 Kevin McCarthy, Director Regional Administrator Radiation Control Unit Region I Department of Environmental Protection U. S. Nuclear Regulatory Commission State Office Building' 475 Allendale Road Hartford, Connectic9t 06106 King of Prussia, Pennsylvania 19406 Bradford S. Chase, Under Secretary First Selectmen Energy Division Town of Waterford Office of Policy and Management Hall of Records 80 Washington Street 200 Boston Post Road Hartford, Connecticut 06106 Waterford, Connecticut 06385 S. E. Scace, Station Superintendent W. J. Raymond, Resident Inspector Millstone Nuclear Power Station Millstone Nuclear Power Station Northeast Nuclear Energy Company c/o V. S. Nuclear Regulatory Connission Post Office Box 128

. Post Office Box 811 Waterford, Connecticut 06385 Niantic, Connecticut 06357 J. S. Keenan, Unit Superintendent Charles Brinkman, Manager Millstone Unit No. 2 Washington Nuclear Operations Northeast Nuclear Energy Company C-E Power Systems Post Office Box 128 Combustion Engineering, Inc.

Waterford Connecticut 06385 12300 Twinbrook Pkwy Suite 330 Rockville, Maryland 20852 3