ML20011E377
| ML20011E377 | |
| Person / Time | |
|---|---|
| Site: | 07003020 |
| Issue date: | 02/02/1990 |
| From: | Macdonald C NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS) |
| To: | Mayer C NAC INTERNATIONAL INC. (FORMERLY NUCLEAR ASSURANCE |
| References | |
| NUDOCS 9002130309 | |
| Download: ML20011E377 (15) | |
Text
,
- -f V
Q
~
1 f.y,~'
2 UNITED STATES t
q i
'c NUCLEAR REGULATORY COMMISSION
).
1 ii
,i (
WASHINGTON, D C 20555 gQ f 4ff) s2
%,*****/
~
h,!d T/ A.
~
M'0"'A
' FEB 2 1990-1 M= ya f
)
f133 SGTB:CRH~
07003020D50R
- Nuclear Assurance Corporation-
- ATTN: Mr. Charles H. Mayer, Project Manager
~
Engineering and Transportation Systems
. 6251 Crooked Creek Road Suite 200 i
Norcross, GA -30092
Dear Mr. Mayer:
This is in regard to a request for approval of a route to be used for transport -
i of spent fuel as contained in your letter of December 14, 1989.
7
- The routeLfrom Fulton, Missouri to Lynchburg, Virginia-(and eventually export-ed from Norfolk, Virginia) as requested in your letter _of December 14, 1989 is judged to meet the regulatory requirements in accordance with 10 CFR 73.37 for shipment of spent fuel and is approved.
In the event your carrier is required to deviate from the approved route, please call the contact listed on page two l
of this-letter.as_soon as possible providing details.
Arrangements with law enforcement agencies along the: route have been completed-by the NRC staff. Data relating to these arrangements and a copy of the approved
- route are enclosed. This information-is to be incorporated into your shipment plans and:provided to your carrier along with instructions regarding its:use.
E Please note that assuring highway safety is the responsibility of the licensee and: carrier:and our approval is not intended to provide relief in this regard.
l During seasonal periods when__ inclement weather with accompanying hazardous road conditions can occur with short notice, the appropriate state-police should be contacted with regard to road conditions before a-shipment commences.
L M ~Please note that the notification requirements.of 10 CFR 73.37(f) and 73.72 L
for each shipment still apply. When makirg a notification to a governor or s
his designee, it should be very specific especially with regard to notification J
o l
w gg. of series shipments. Written notification must designate exactly how many in-L L om. - dividual shipments are to be included.
In the event the number of shipments JE8 in a series is revised,-the changed notification should indicate that it is a jg revision of the original notification and an increase or decrease in the
/f p
wh UP04REMOVAldWATTAtliEHTTlilSDD El;NI10 ent TransmJi ederewith g y,f
$M Doc L d$cc itains Safcpftds information j
ll&
Enc /c swe has baa n Scuy h Q,
SARADS EMNft' If4 ls. /
~
ft s
.n
- 7 tMr. Charles H. Mayer FEB2 1990 number of shipments.
In addition, the change notificaiion should specify that the information for any of the shipments in the revised serien may not be decon.
trolled until-ten days after the arrival at the destination' of the last shipment in that series.
Should you require additional information or have questions concerning this matter, please contact Charles Hillman of sqy staff at (301) 492 0488.
Sincerely,
& Yar$Do h4-L M
Charles E. MacDonald, Chief Transportation Branch Division of-Safeguards and Transportation, NMSS
Enclosure:
As stated Fulton/Lynchbarg(133) 07003020050R Distribution:
w/ enclosure w/o enclosure Docket File 70-3020-NMSS/SGTB r/f CH111 man Case File'70-3020 RFonner JCook Regions 2 & 3 GSjoblom RBurnett DWeiss
-CMacDonald PDR(Santized)
(
t 0FC: SG B
- SGT
- SGTB 4
...............I boe[..........--..I.......--.......--.
DATE:0)/h/90 : 2 ///90 : L/ / /90 :
OFFICIAL RECORD COPY LTR 10 NUCLEAR ASSURANCE CORP
g w.
$1'33 /
j_
a 9
i k
s i
SPENT NUCLEAR FUEL ROUTE CALLAWAY PLANT, FULTON, MISSOURI TO i
t BABCOCK AND WILCOX FACILITY LYNCHBURG,-VIRGINIA FEBRUARY 1990'
'f J
d i
/.
1 t
.r%..."
. :4 L 4
I!U P1 133' e
'E
SUMMARY
OF LEA RESPONSE CAPIBILITIES AND SAFE HAVENS--
ROAD TRANSPORTATION ROUTE CALLAWAY PLANT, FULTON, MISSOURI TO BABCOCK AND WILCOX FACILITY, LYNCHBURG, VIRGINIA n
NOTE:
Safe havens are indicated on the route strip charts by a lower case u
. letter of the alphabet in parenthesis.
These safe havens were
' designated by the NRC route analysis teams with the assistance of law enforcement agencies along.the route, as available, for tempo-rary refuge.until appropriate assistance arrives.
The basic criteria used to identify a-safe haven were availability of a large parking y
area, nighttime lighting, where possible, and rapid law enforcement response to the safe haven.
Should a safe haven be required, refer to the following state-summaries for specific identification and location.
t
'l
- la -
February 1990 4
p"-
p 133 ROAD TRANSPORTATION ROUTE s.
CALLAWAY PLANT, FULTON, MISSOURI TO
{
THE BABC0CK AND WILCOX FACILITY, LYNCHBURG, VIRGINIA MISSOURI i
1.
MO-CC north to MO-0*
6 miles L
2.
MD 0 west to US-54*
9 miles 3.
US-54 north to I-70*
7 miles t
4.
I-70 east to US-40 60 miles 5.
US-40 south and east to I-270 26 miles 6.
1-270 south and east to I-255 13 miles 7.
1-255 east to the Illinois state line 3 miles Subtotal T24 miles ILLINOIS t
B.
1-255 east to I-64 16 miles 9.
1-64 east to I-57 66 miles 10.
1-57 south to I-24 51 miles 11.
1-24 south to Kentucky state line 35 miles i
Subtotal 168 miles i
KENTUCKY 12.-
I-24 south / east to Tennessee state line 123 miles Subtotal 123 miles
- TENNESSEE 13.
1-24 south / east to I-65 45 miles i
14.
I-65 south to I-40 35 miles 15.
1-40 east to I-81 200 miles 16.
I-81 north / east to Virginia state line 90 miles Subtotal 370 miles VIRGINIA 17.
I 81 north to I-581 140 miles 18.
1-581 east to US-460 6 miles 19.
US-460 east to Mt. Athos Road
- 61 miles
- 20. Mt. Athos Road to B&W Facility
- 3 miles Subtotal 210 miles TOTAL 995 miles
- Access to or exit from Interstate or State Preferred Routes.
1 February 1990
33I b,
[00DANDFUELSTOPS 4
I 1The businesses and locations listed below were identified by the NRC route l
analysis team) as possible food and fuel stops. All possible stops along the b
route are not listed._ Only a few of the locations were visited by the NRC teams.
In order to be listed, food and fuel stops were required to be close to the route and offer basic truck services as well as food.
MISSOURI L
1.
Ray's Truck Stop.
I-70, exit 161, Williamsburg, Montgomery County.
ILLINDIS 1.
Little Nashville Inc. Truck Stop.
1-64, exit 50, Washington County, KENTUCKY 1.
Phillips 66 Truck Stop.
I-24, McCracken County.
t-2.
Shell Truck Stop.
1-24. Trigg County.
'1.
Phillips 66 Truck Stop.
1-24, Robertson County.
2.
Phillips 66 Truck Stop.
I-24, Wilson County.
3.
Union 76 Truck Stop.
1-40, Cocke County.
VIRGINIA 1.
Wilderness Road Union 76 Truck Stop.
Intersection of I-77 and I-81, exit 22' Wythe County.
i
- t, t
2 February 1990
Mtsseurt 133 Statewide Emergency uundser: 1-800-525-5555 Elettem/ST Lattts ASEA FULTON NP (314) 642-2583 ur (314) 434 4500 S (314) 89P-2724 S (314) 642-T291 NT egy CW 9/19 Conse:
MT g-- y C# 9/19, t MP, S LEA:
MP, 5 CALLauAY WO l IL NUCLEAR E eElrirmoed/St Louis Aree POWER oFutten l
PLAWT
...=
- =........= _
1-3
-2
+3
-4 l
l 1
-5
+6 1
-r l
l Cottomey
]
faentgespry l
uorren
]
St. Chortes
{
St teuis l
C1LES IN l
Cotety l
Cotety
{
Commty l Cotety l
County l
a miso CTiOs 39 I
2e i
17 I
si i
17 i
i I
i I
i I
TOTAL l
l l
l l
l CILES 0
39 39 76 107 124 ROAD TRANSPORTATION WOtffE - Cettemoy Plant, FwLten, IED to the Sebcock EET eruf uitcom Ceupuny facility, Lynchburg, vm
- 01 Suo-CC north to 840-0 (6 arites);
O LEA Wesponse Center
- 92.
iud-O west to tf5-54 (9 miles);
MP/SP nighwey Petrot/ State Police
- 03.
175-54 north to I-79 (T miles);
S Sheriff
+96.
f-70 eest to 175-40 (60 sites);
CP City Potice
+05.
05-40 south emi eest to 1-270 (26 wites);
C'P County Police
- 06.
I-270 south and cost to I-255~(13 arites);
CB Radio tecnitored (Sese) e (1-255 is the contimmption of I-270)
C8 Radio Monitored (Cer)
- ST.
1-255 eest to the Ittireis stete time (3 mites);
c-y Cn/mo.
Chennet seenitored R
react Grote MT teobite Telephone (Useable)
E Escort t=<psired
! r +,o i
., k ILLisets 133 e.
Statewide Emergency mudper: 911 Nf. WWo0W COLLIWSVILLE sp (618) 562-21T1
- SP (618) 366-36830 WTe CN9,R Comuc 987 m CN 9, R SP.
LE*.:
SP 9101 IL.
est. wernen I
sCottinevitte I
(off route) 14 i
I I
i I
I I nonroe i
St. Ct.ir i
C I
us.ninete i
m ferson i
reweten i
c:itES in i
County i Cower i
i i
Co-wy I
Cower i
Cower i
autiso Crim I
3 1
36 i
i i
25 1
2e l
tT I
i i
i i
I I
I a
Total I
I I
e i
i i
i CILES 126 127 161 e 169 196 229 237 WW TWAWSPURTATION WERffE - Collemer Plant, Ftdten, 980 to t9ee Salueettt 5
KEY and Wilces Company facility, Lync9dpwry, we
- 08.
1-255 eest to I-M (16 miles);
9 o
LEA Response Center
- 99 I-M eest to 1-57 (66 miles);
NP/SP Mighuey Petrol / State Police
- 19.
1-57 scutti to 1-26 (51 miles);
S Sheriff CP City Police C'P County Potice C5 Radio soonitored (tese) e C8 tedio peonitored (Car) e CN/co.
Cherwiet peonitored l
t Weect Groep l
NT
- tobile Telephone (tfeestde)
E Escort Required
- --n
e 0
s M
~
.llI1iI5 3
e t
e k
_1 t
2 c
e 1
e b
5 eR s
9 rC bW 3
o s
m O,
2 g
2 er
)
2 6
h u s
lllllI 3 t b e
0 3
h l
oc 1
l W
t n e
+
y 1
4 t
) 3 7
s2 8
e1
,y l (
r nt i
ei me k
t l n
s di 5i c
3l t
e F a
(
e
,f et 1
h e, 6 y
t y ne nn it 1 5 c w2 e a l s 25 eo l p 7 5 rC P m e
a.
35 t
o t
62 e
rC
- a
)
m e
) t 5 2 u m ss e
82 e
eo e
t d
t c l y i
D ) 0 d u.
t t i t m
w L 20 l
o.
e E 08 er ei met C w w
i a
F ( 1 f f.
4 1 t e t
I 5 -
yf. lll1iI1
$ nh t
T 3
( et o.
E K
S R P P t
P e
MS S M
S n(
T 6
o Y
e U
2 et R
O h
W 1 t t s
N ooo O
t t c I
/
T hhh A
t t t T
uuu R
o o o O
sss r
P de 5
764 i2 W
522 row2 A
t o W
1 1 1 t C T
e S
W 91 2 O
1 1 1 Y
W t
D U
T
. 2 TN E
. 1 5
2 llj. [llliI9 Eu 2
/s t
f y
to t
ns cui s
i a o t
sC t
s I
en 7
.. l{lliI7 2
~
r nei o
1 s w2 no h C o
J
.. 1
. 1 6
. lllliI5 2
e
)
c i
)
e e) t n
lo s r b
e m-r P
e e e
D C e
m :_ 1 a
9 e
( (
s rt U
l ea dd
(
1 t
t t e ed 1
t C nS r r e e
9 w
e/
oor nd i
Cl t t o o e o
eiit h r er cnni pi W
ngl q e u s t eio o ne cl MM o
o M e ee oP i
p l P oo rT R s
, f o i i t G e
_ f P yd d e et y
0 l r smtcio 7*
~
R
_ i t a
. 1
. llliIi3 r ynR R
cn 2
A fet u e ab c e
Ei hi oB8h eo s g
L 8
SC CC CC R ME t
res
-E m
e O
d I
i T
w nc e
ii t
o a
S s t S P
o E i a E S
N t
1 I
C L
Ma T M K.
- M s C 'C m cN S
u 3
m A
L t t L Y.
/
P
/
3 t
o E
iu oi E.
P P
T C R ME 1
- l 4
l l
!ljifIll!!l
~. _ _ _.. -.. _
.a.
ItENTUtstT/TE4NESSFE 133 -
KY Stetevide -.,-c 1 uwster: 1-800-222-5555 TW Stateufde Emergency musters ihme MIDISONVILLE SP 1-800-222-5555 SP (502) 676-3313 1
Mt Conus-SP LEA:
KYlTW enedisemitte l
(off route) l
=..............__......
- =.............................=
..........____--===
122 I
I I
i l*n I
lLivingston l Lyon l
C l
Trigg l
Christien -
l seentgesery l
l County 1
Cewsty 1
Cooney -
t nitES in i C tv l
County l
e utiSoiCTim i
6 I
17 i
i i
n i
24 l
is I
I I
i d
I I
i i
I I
I I
TotAt i
I I
u f;ItES 350 356 373 e 378 391 415 433 1
1 KEY BORD TRANSPGtTATION RWTE - Cetteusy Plant, Futten, MO to the Sebcock c
and Wilcout Company facility, Lynchbury, WA I
- 12. 3-24 south /eest to the Terwiesee= state line (123 miles);
o LEA mesponse center j
- 13.
I-24 south /eest to I-95 (45 mites);
MP/SP Mighuey Petrol / State Police 5
Sheriff CP City Police l
C'P County Police CB Radio Monitored (geoe) i e
C8 Radio Monitored (Cer) l C--,
C /Wo.
Channet Monitored R
Reect Group Mi mobile Telephone (Useetde)
E Escort Recysired,#,,
TENNESSEE 133 Statewide Emergency Wis6ert mone coolteviile NASWWILLE WP (615) 528-9696 nP (615) 7&1-2060 CP.(615) 526-2125 or 911 CP (615) 526-2300 MT t - CN 19, R MT come:
eCookevilte E seeshvitte (b)
-_-.................................. = _--
113 l
+14 l
- t5 l
l l
l Chetham l
Devidson l
Wilson l
Smith l
Puttum l'
P.lLES IN
]
Cotrity l
Comty l
County l
County l Cosetty l
JL21SDICTION l
14 l
28 l
27 l
16 l
38 l
l 1
1 I
I I
TOTAL l
l l
l l
l 556 KILES 433 447 475 502 518 ROW TRANSPORTATION ROUTE - Cottauer Plant, Futton, MO to the Sebcocit and witcom Company facility, Lynchburg, vm KEY
- 13. I-24 south / cost to I-65 (45 miles);
LEA Response Center
- 14 1-65 south to I-40 (35 miles);
MP/SP Mighuey Petrot/ State PotIce
- 15.
1-40 eest to I-81 (200 miles);
5 Sheriff CP City Police C'P County Police C8 Radio Monitored (Sese) gg C8 Radio Monitored (Cor) c C2/No.
Channet Monitored R
React Groi,
Nobile Telephone (Useebte)
MT E
Escort Required Fet>-98.
TEnuESSEE 133 Statewide L. m ~i Ihssbers mene RNONvfLLE NP (615) 695-7311 CP (615) 521-1200 or 911 s
E etnonvitte
==...................................................................
115 I
I I
I l
Cueertens l
Rosn i
t I
rne=
l MILES IN l
Commty l
County l
o l
Coety
{
JuRiso Crios 1
3e l
25
{
u i
39 I
I I
d I
I TOTAL l
l
_. I e
{
l LILES 556 596 619 n 625 466 ROAD TRANSPORTAfl0E IttRffE - Cetteusy Plent, Fwiten, MD to tfie Sebcock KEY and Witcon Cemqueny facility, Lynefthurg, DE
- 15. 1-40 eest to !-81 (299 adtee);
O LEA Response Center NP/SP Mighuey Petrol / State Police Sheriff CP City Police C'P Co mty Potice Cs Radio esonitored (tese) e CB Radio Monitored (Cor) a CN/Wo.
Chemet Monitored R
Reect Group MT peabile Telephone (Useebte)
E Escort Regsired r+9e l
l
?
l 1
~
TEWWESSEE 133 4
Statewide Camergency thenbert gene Kl#E3 PORT MORRISTOWN S (615) 586-1213 SP (615) 349-6144 CP (615) 586-3781 e
NT m e CN 9/19, R NT e o CN 9/19, R Comun:
TW l M 4
enorristoem eEingeport l
(off route) l (off route) 115 i
1*16 l
l 1
l S
l Jefferson l
Nos6 ten l
Greene l
Seat tiven l
C1LES IN l
e l
Commty l
Cotnty l
Commty l
Ceemty l
JuRiso Cries i
v l
25 g
sz l
35 l
23 l
1 i
i i
i I
I i
TOTAL I
e i
I I
I I
EILES
- 664, r
670 695 7zT 762 785 4
l i
Roe TRANSPORTATIDs actNE - Cettemoy Plant, Futten, MD to tite Gebcock KEY aruf Wiicost Coupony fociiIty, Lynchburg, M
- 15. 1-40 cost to I-81 (200 orites);
o LEA Response Center
- 16.
f-81 north / cost to the Virginie stete (Ine (90 arites);
NP/SP nighuey Petret/ State Police S
Sheriff CP City Police C'P County PotIce CB Radio Monitored (Bese) e CS Radio Monitored (Cer) o CN/No.
Channet Monitored j
R React Group
~
4 MT Mobile Telephone (Useebte)
E Escort Reesired Fee-90 1
1 4
h m
. m 2
__.,_a
..-4
+-.
se
,e+,_.r-.,.,-,,,,,,,-,#
,,,,..,,,.-,,,-y,-,,4,
,m.,
~,
e
.o-vtestata -
133 itetewide Emergency thabert none SRISTOL ASINGTON SWutt0N WYTWEVILLE PUUt9K!
SP 1-800-542-8716 S (703) 628-7183 S (703) 783-7206 sr 1-800-542-8775 s (703) 988-214e SP (703) 228-3131 SP (703) 228-31318 Comer:
MT e m CM 9 MT MT M sus CN 9 MT m CN 9, R MT o CN 19, R c CM 9/19 S
LEA:
'P S
S SP TN I VA eurtbevitte eruteski
[seristot embington eMorton I
1*17 I
I I
i I
we*ington I
s=rt*
I wrthe i
Pwieds I
1 r.itES in i
Cowity 1
County l
County i
County 1
auRisoCTion 1
34 1
23 1
29 1
18 I
I I
I I
I TOTAL i
i I
i I
mites 785 819 862 8 71 809 ROAD TRAWSPORTATION Rot;TE - Cottousy Plant, Fulton, MD to the Debcock f'
KEY and Wiicon Company foci 1ity, Lync%ur9, WA
- 17.
1-81 corth to I-581 (140 mites);
O LEA Response Center HP/SP Mighuey Petrot/ State Police S
Sheriff CP City Police C'P County Police
- For use between the hours of 8 a.m. and 5 p.=. opty, CS Radio Monitored (Seoe) e CB Radio Monitored (Car) a C::/Wo.
Channet Monitored R
Reect Groep MT 9tobile Telephone (Useebte)
E Escort Regsfred F*98 ~
]
VIRGlWIA 9
133 Statewide Emergency skaber Wone SEDf0RD LTWCMOURG SALEM /ROANOKE SP 1-800-542-5959 SP 1-800-542-5959 sr 1-800-552-0916 4
sP (703) 380-2019 SP (703) 586-9611e SP (804) 528-653M sti e CM 9/19, R MT a CW9,R MT a CN 9. R Conun:
9ASCott Aeo WILC0K seedford etynchburg CtpuPANY -
E esetenVRoanoke TACILITY
---..=---
_--.............................................=-_ -
..........=_== --__
l17 l
- 18
- 19 l
-l l
- 20 l
l stentgomery l
Roanoke l
Botetourt l
9edford l
Cagbet t l
titEs in I
County l
County l
County 1
County l
County l
.1URISDICTION l
24 l
21 l
16 l
31 1
14 i
i I
I i
i i
TOTAL l
l l
l l
l 913 934 950 981 995 MILES 889,.
ROW TRANSPORTATION ROUTE - Cettemoy Plant, Fulton, M0 to *he Sebcock KEY and Wilcox ra-r=ny facility, Lynchburg, vn fy. 1-81 north to I-581 (140 mites);
f o
LEA Response Center
- 18.
1-581 eest to 175-460 (6 miles);
MP/SP Mighwey Petrol /stete Police
- 19.
175-460 eest to Mt. Athos Reed (61 miles); and l
s sheriff
- 20.
Mt. Athos Road to the t & W facility (3 miles).
l CP City Police l
C'P County PotIce C8 Radio Monitored (Bese) f a
l C8 Radio Monitored (Car) cy
- For use between 8 a.m. and 5 p.m. only.
C:/No.
Channet feonitored R
React Group MT Mobile Telephone (Useable)
E Escort Required F+90 l
-...., -.. - -, ~. _,,. -. -,., -
-